4.3 Article

Cerclage Wire-Plate Composite for Fixation of Quadrilateral Plate Fractures of the Acetabulum: A Checkrein and Pulley Technique

Journal

JOURNAL OF ORTHOPAEDIC TRAUMA
Volume 24, Issue 5, Pages 323-328

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/BOT.0b013e3181c90bbe

Keywords

acetabulum; fracture; quadrilateral plate; medial wall; cerclage wires; spring plates

Ask authors/readers for more resources

Acetabular fractures with complete or incomplete quadrilateral plate separation frequently present with central displacement of the femoral head. Failure of stable fixation of medial wall fractures leaves residual subluxation despite reduction of other fracture components. Several fixation techniques may be either technically demanding or insufficient for stable fixation in conditions of comminution, osteoporosis, or neglected injuries. The proposed wire-plate composite uses a reconstruction spring plate over the pelvic brim for medial wall buttressing. One hole on its true pelvic limb provides a pulley to deviate a cerclage wire or cable passed through the greater sciatic notch into the true pelvis. This enhances buttressing against medial protrusion. Application through anterior approaches is simple and fixation is reliable in difficult fractures without the risk of joint penetration because all quadrilateral plate buttressing implants remain extraosseous.