Influence of chirping the Raman lasers in an atom gravimeter: Phase shifts due to the Raman light shift and to the finite speed of light
Published 2015 View Full Article
- Home
- Publications
- Publication Search
- Publication Details
Title
Influence of chirping the Raman lasers in an atom gravimeter: Phase shifts due to the Raman light shift and to the finite speed of light
Authors
Keywords
-
Journal
PHYSICAL REVIEW A
Volume 92, Issue 6, Pages -
Publisher
American Physical Society (APS)
Online
2015-12-10
DOI
10.1103/physreva.92.063617
References
Ask authors/readers for more resources
Related references
Note: Only part of the references are listed.- CCM.G-K2 key comparison
- (2015) Olivier Francis et al. METROLOGIA
- Experimental assessment of the speed of light perturbation in free-fall absolute gravimeters
- (2015) H Baumann et al. METROLOGIA
- Measurement of thespeed-of-lightperturbation of free-fall absolute gravimeters
- (2014) Ch Rothleitner et al. METROLOGIA
- The investigation of a μGal-level cold atom gravimeter for field applications
- (2014) Bin Wu et al. METROLOGIA
- Stability comparison of two absolute gravimeters: optical versus atomic interferometers
- (2014) P Gillot et al. METROLOGIA
- Investigating the frequency-dependent amplification of a tapered amplifier in atom interferometers
- (2014) Su Zhan et al. OPTICS LETTERS
- Effective velocity distribution in an atom gravimeter: Effect of the convolution with the response of the detection
- (2014) T. Farah et al. PHYSICAL REVIEW A
- Sensitivity limits of a Raman atom interferometer as a gravity gradiometer
- (2014) F. Sorrentino et al. PHYSICAL REVIEW A
- First gravity measurements using the mobile atom interferometer GAIN
- (2013) M. Hauth et al. APPLIED PHYSICS B-LASERS AND OPTICS
- Compact cold atom gravimeter for field applications
- (2013) Yannick Bidel et al. APPLIED PHYSICS LETTERS
- The European Comparison of Absolute Gravimeters 2011 (ECAG-2011) in Walferdange, Luxembourg: results and recommendations
- (2013) Olivier Francis et al. METROLOGIA
- Demonstration of an ultrahigh-sensitivity atom-interferometry absolute gravimeter
- (2013) Zhong-Kun Hu et al. PHYSICAL REVIEW A
- The 8th International Comparison of Absolute Gravimeters 2009: the first Key Comparison (CCM.G-K1) in the field of absolute gravimetry
- (2012) Z Jiang et al. METROLOGIA
- Measurement of Local Gravity via a Cold Atom Interferometer
- (2011) Lin Zhou et al. CHINESE PHYSICS LETTERS
- Comparison of 3 Absolute Gravimeters Based on Different Methods for the e-MASS Project
- (2011) Anne Louchet-Chauvet et al. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT
- Second-order Doppler-shift corrections in free-fall absolute gravimeters
- (2011) Ch Rothleitner et al. METROLOGIA
- Reply to ‘Comment on second-order Doppler-shift corrections in free-fall absolute gravimeters’
- (2011) Ch Rothleitner et al. METROLOGIA
- Relativity, Doppler shifts and retarded times in deriving the correction for the finite speed of light: a comment on ‘Second-order Doppler-shift corrections in free-fall absolute gravimeters’
- (2011) V D Nagornyi et al. METROLOGIA
- Correction due to the finite speed of light in absolute gravimeters
- (2011) V D Nagornyi et al. METROLOGIA
- The influence of transverse motion within an atomic gravimeter
- (2011) Anne Louchet-Chauvet et al. NEW JOURNAL OF PHYSICS
- A cold atom pyramidal gravimeter with a single laser beam
- (2010) Q. Bodart et al. APPLIED PHYSICS LETTERS
- Comparison between two mobile absolute gravimeters: optical versus atomic interferometers
- (2010) S Merlet et al. METROLOGIA
- Off-resonant Raman transition impact in an atom interferometer
- (2008) A. Gauguet et al. PHYSICAL REVIEW A