4.7 Article

Quantitative Evaluation of Cerebral Blood Flow and Oxygen Metabolism in Normal Anesthetized Rats: 15O-Labeled Gas Inhalation PET with MRI Fusion

Journal

JOURNAL OF NUCLEAR MEDICINE
Volume 54, Issue 2, Pages 283-290

Publisher

SOC NUCLEAR MEDICINE INC
DOI: 10.2967/jnumed.112.109751

Keywords

O-15-gas PET; CBF; OEF; CMRO2

Funding

  1. Ministry of Education, Culture, Sports, Science, and Technology (MEXT), Japan [21591561]
  2. Grants-in-Aid for Scientific Research [21591561] Funding Source: KAKEN

Ask authors/readers for more resources

PET with O-15 gas has been used for the quantitative measurement of cerebral blood flow (CBF), cerebral metabolic rate of oxygen (CMRO2), oxygen extraction fraction (OEF), and cerebral blood volume (CBV) in humans. However, several technical difficulties limit its use in experiments on small animals. Herein, we describe the application of the O-15 gas steady-state inhalation method for normal anesthetized rats. Methods: Eight normal male Sprague-Dawley rats (mean body weight +/- SD, 268 +/- 14 g) under anesthesia were investigated by O-15-labeled gas PET. After tracheotomy, an airway tube was placed in the trachea, and the animals were connected to a ventilator (tidal volume, 3 cm(3); frequency, 60/min). The CBF and OEF were measured according to the original steady-state inhalation technique under artificial ventilation with O-15-CO2 and O-15-O-2 gases delivered through the radioactive gas stabilizer. CBV was measured by O-15-CO gas inhalation and corrected for the intravascular hemoglobinbound O-15-O-2. Arterial blood sampling was performed during each study to measure the radioactivity of the whole blood and plasma. MR image was performed with the same acrylic animal holder immediately after the PET. Regions of interest were placed on the whole brain of the PET images with reference to the semiautomatically coregistered PET/MR fused images. Results: The data acquisition time for the whole PET experiment in each rat was 73.3 +/- 5.8 (range, 68-85) min. In both the O-15-CO2 and the O-15-O-2 studies, the radioactivity count of the brain reached a steady state by approximately 10 min after the start of continuous inhalation of the gas. The quantitative PET data of the whole brain were as follows: CBF, 32.3 +/- 4.5 mL/100 mL/min; CMRO2, 3.23 +/- 0.42 mL/100 mL/min; OEF, 64.6% +/- 9.1%; and CBV, 5.05 +/- 0.45 mL/100 mL. Conclusion: Although further technical improvements may be needed, this study demonstrated the feasibility of quantitative PET measurement of CBF, OEF, and CMRO2 using the original steady-state inhalation method of O-15-CO2 and O-15-O-2 gases and measurement of CBV using the O-15-CO gas inhalation method in the brain of normal anesthetized rats.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available