Journal
PATHOBIOLOGY
Volume 82, Issue 1, Pages 48-52Publisher
KARGER
DOI: 10.1159/000375264
Keywords
Acute hepatitis; Digital image analysis; Elastic fibrosis; Liver stiffness measurements; Orcein staining; Staining methods; Transient elastography
Categories
Ask authors/readers for more resources
Objective: To compare Masson's trichrome (MT), Sirius red (SR) and orcein staining in acute hepatitis (AH) and to correlate them with transient elastography (TE), a noninvasive method to assess hepatic fibrosis. Methods: We evaluated liver stiffness by TE in a cohort of 34 consecutive patients and assessed MT-, SR- and orcein-stained biopsies using the METAVIR scoring system and digital image analysis (DIA). Results: MT and SR both showed severe fibrosis (stage III-IV, DIA = 12.7%). Orcein showed absent or mild fibrosis (stage 0-II, DIA = 4.4%; p < 0.05). In 29/34 cases (85%), stiffness values were > 12.5 kPa, in keeping with SR/MT but not with orcein results. Conclusions: Even though in AH true elastic fibrosis is typically absent or mild, TE shows elevated stiffness values, in keeping with SR/MT evaluations. If not properly evaluated in the clinical context, these results would lead to an overestimation of fibrosis. Orcein is the only staining able to evidence the absence of true elastic fibrosis, which is a typical feature of AH. This is the first study comparing different staining procedures performed on AH biopsies by DIA versus TE. (C) 2015 S. Karger AG, Basel
Authors
I am an author on this paper
Click your name to claim this paper and add it to your profile.
Reviews
Recommended
No Data Available