4.5 Article

Simultaneous determination of vitexin-4-O-glucoside, vitexin-2-O-rhamnoside, rutin and vitexin from hawthorn leaves flavonoids in rat plasma by UPLC-ESI-MS/MS

Publisher

ELSEVIER
DOI: 10.1016/j.jchromb.2010.05.023

Keywords

Vitexin-4 ''-O-glucoside; Vitexin-2 ''-O-rhamnoside; Rutin; Vitexin; Hawthorn leaves flavonoids; UPLC-ESI-MS/MS

Ask authors/readers for more resources

A sensitive and accurate ultra-performance liquid chromatography electrospray ionization tandem mass spectrometry (UPLC-ESI-MS/MS) method was developed and validated for the simultaneous determination of vitexin-4 ''-O-glucoside (VGL), vitexin-2 ''-O-rhamnoside (VRH), rutin (RUT) and vitexin (VIT) in rat plasma after intravenous administration of hawthorn leaves flavonoids (HLF). Following protein precipitation by methanol, the analytes were separated on an ACQUITY UPLC BEH C-18 column packed with 1.7 mu m particles by gradient elution using a mobile phase composed of acetonitrile and water (containing 0.1% formic acid) at a flow rate of 0.20 mL/min. The analytes and diphenhydramine (internal standard, IS) were detected in the multiple reaction monitoring (MRM) mode by means of an electrospray ionization (ESI) interface (m/z 292.96 for vitexin-4 ''-O-glucoside, m/z 293.10 for vitexin-2 ''-O-rhamnoside, m/z 299.92 for rutin, m/z 310.94 for vitexin and m/z 166.96 for IS). The calibration curve was linear over the range 10-40,000 ng/mL for vitexin-4 ''-O-glucoside, 10-50,000 ng/mL for vitexin-2 ''-O-rhamnoside, 8-1000 ng/mL for rutin and 16-2000 ng/mL for vitexin. The intra- and inter-run precisions (relative standard deviation, RSD) of these analytes were all within 15% and the accuracy (the relative error, RE) ranged from -10% to 10%. The stability experiment indicated that the four analytes in rat plasma samples and plasma extracts under anticipated conditions were stable. The developed method was applied for the first time to pharmacokinetic studies of the four bioactive compounds of hawthorn leaves flavonoids following a single intravenous administration of 20 mg/kg in rats. (C) 2010 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available