4.4 Article

Multi-channel wireless mapping of gastrointestinal serosal slow wave propagation

Journal

NEUROGASTROENTEROLOGY AND MOTILITY
Volume 27, Issue 4, Pages 580-585

Publisher

WILEY
DOI: 10.1111/nmo.12515

Keywords

dysrhythmia; gastric electrical activity; wireless signal acquisition

Funding

  1. National Science Foundation [ECCS 1337965]
  2. New York Institute of Technology Institutional Support for Research and Creativity fund
  3. Health Research Council of New Zealand
  4. NIH [R01 DK64775]

Ask authors/readers for more resources

Background High-resolution (HR) extracellular mapping allows accurate profiling of normal and dysrhythmic slow wave patterns. A current limitation is that cables traverse the abdominal wall or a natural orifice, risking discomfort, dislodgement or infection. Wireless approaches offer advantages, but a multi-channel system is required, capable of recording slow waves and mapping propagation with high fidelity. Methods A novel multi-channel (n = 7) wireless mapping system was developed and compared to a wired commercial system. Slow wave signals were recorded from the porcine gastric and intestinal serosa in vivo. Signals were simultaneously acquired using both systems, and were filtered and processed to map activation wavefronts. For validation, the frequency and amplitude of detected events were compared, together with the speed and direction of mapped wavefronts. Key Results The wireless device achieved comparable signal quality to the reference device, and slow wave frequencies were identical. Amplitudes of the acquired gastric and intestinal slow wave signals were consistent between the devices. During normal propagation, spatiotemporal mapping remained accurate in the wireless system, however, during ectopic dysrhythmic pacemaking, the lower sampling resolution of the wireless device led to reduced accuracy in spatiotemporal mapping. Conclusions & Inferences A novel multichannel wireless device is presented for mapping slow wave activity. The device achieved high quality signals, and has the potential to facilitate chronic monitoring studies and clinical translation of spatiotemporal mapping. The current implementation may be applied to detect normal patterns and dysrhythmia onset, but HR mapping with finely spaced arrays currently remains necessary to accurately define dysrhythmic patterns.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available