4.4 Article

Early Healing of Nanothickness Bioceramic Coatings on Dental Implants. An Experimental Study in Dogs

Publisher

WILEY
DOI: 10.1002/jbm.b.31090

Keywords

implant design; in vivo; surface modification; coating(s); biomechanics

Ask authors/readers for more resources

Thick bioceramic coatings like plasma sprayed hydroxyapatite have been shown to increase the overall tissue response and biomechanical fixation of dental implants. However, the presence and potential fracture of a bone-coating-metallic substrate interface at long times after implantation led these implants to fall from favor in clinical practice. The purpose of this study was to evaluate the biomechanical fixation and biological response of Ca- and P-based, 20-50 nm thickness bioceramic deposition on a previously alumina-blasted/acid-etched Ti-6Al-4V implant surface in a dog model. Cylindrical alumina-blasted/acid-etched (AB/AE) (Control, n = 16), and Nanothickness bioceramic coated AB/AE(Nano, n = 16) implant surfaces were surgically placed in dogs proximal tibia and remained for 2 and 4 weeks in vivo. Following euthanization, the implants-in-bone were mounted in epoxy and pullout at a 0.5 mm/min rate. Following mechanical testing, the specimens were decalcified and processed (Hematoxylin and Eosin) for standard transmitted light microscopy evaluation. Percent bone-to-implant contact (BIC) to the pulled out implant surface was determined through computer software. Statistical analyses were performed by one-way ANOVA at 95% level of significance and Tukey's post-hoc multiple comparisons. No significant differences in pullout force were observed (p > 0.88): 2W Control (212.08 +/- 42.96 N), 2W Nano (224.35 +/- 42.97 N), 4W Control (207.07 +/- 42.97 N), and 4W Nano (190.15 +/- 45.94 N). No significant differences in %BIC were observed (p > 0.94): 2W Control (72.66 +/- 8.51), 2W Nano (69.44 +/- 8.51), 4W Control (70.44 +/- 8.51), and 4W Nano (69.11 +/- 9.09). It is shown that 20-50 nm thickness bioceramic depositions onto previously alumina-blasted/acid-etched substrates did not improve the biomechanical fixation and the BIC at early implantation times, and studies concerning shorter and longer implantation times are recommended for confirmation or before a conclusion can be made. (c) 2008 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 88B: 387-393, 2009

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

Article Materials Science, Ceramics

Bioactivity of strontium-monetite coatings for biomedical applications

Daniel Navarro da Rocha, Leila Rosa de Oliveira Cruz, Jose Brant de Campos, Jheison Lopes dos Santos, Rubens L. Santana Blazutti Marcal, Dindo Q. Mijares, Rafael Maza Barbosa, Paulo G. Coelho, Marcelo H. Prado da Silva

CERAMICS INTERNATIONAL (2019)

Article Surgery

Alveolar Ridge Expansion: Comparison of Osseodensification and Conventional Osteotome Techniques

Jimmy H. Tian, Rodrigo Neiva, Paulo G. Coelho, Lukasz Witek, Nick M. Tovar, Ivan C. Lo, Luiz F. Gil, Andrea Torroni

JOURNAL OF CRANIOFACIAL SURGERY (2019)

Article Materials Science, Ceramics

Nanomechanical and microstructural characterization of a zirconia-toughened alumina composite after aging

A. C. O. Lopes, P. G. Coelho, L. Witek, E. B. Benalcazar Jalkh, L. A. Genova, K. N. Monteiro, P. F. Cesar, P. N. Lisboa Filho, E. T. P. Bergamo, I. S. Ramalho, E. A. Bonfante

CERAMICS INTERNATIONAL (2019)

Article Dentistry, Oral Surgery & Medicine

Zirconia-reinforced lithium silicate crowns: Effect of thickness on survival and failure mode

Edmara T. P. Bergamo, Dimoruan Bordin, Ilana S. Ramalho, Adolfo C. O. Lopes, Rafael S. Gomes, Marina Kaizer, Lulzasz Witek, Esteuam A. Bonfante, Paulo G. Coelho, Altair A. Del Bel Cury

DENTAL MATERIALS (2019)

Article Engineering, Biomedical

The effect of platelet-rich fibrin exudate addition to porous poly(lactic-co-glycolic acid) scaffold in bone healing: An in vivo study

Lukasz Witek, Han Tian, Nick Tovar, Andrea Torroni, Rodrigo Neiva, Luiz F. Gil, Paulo G. Coelho

JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS (2020)

Review Dentistry, Oral Surgery & Medicine

Biomaterial and biomechanical considerations to prevent risks in implant therapy

Estevam A. Bonfante, Ryo Jimbo, Lukasz Witek, Nick Tovar, Rodrigo Neiva, Andrea Torroni, Paulo G. Coelho

PERIODONTOLOGY 2000 (2019)

Article Engineering, Biomedical

Implant-abutment fit influences the mechanical performance of single-crown prostheses

Ilana S. Ramalho, Edmara T. P. Bergamo, Lukasz Witek, Paulo G. Coelho, Adolfo C. O. Lopes, Estevam A. Bonfante

JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS (2020)

Article Surgery

Bone Tissue Engineering in the Growing Calvaria Using Dipyridamole-Coated, Three-Dimensionally-Printed Bioceramic Scaffolds: Construct Optimization and Effects on Cranial Suture Patency

Samantha G. Maliha, Christopher D. Lopez, Paulo G. Coelho, Lukasz Witek, Madison Cox, Alan Meskin, Sejndi Rusi, Andrea Torroni, Bruce N. Cronstein, Roberto L. Flores

PLASTIC AND RECONSTRUCTIVE SURGERY (2020)

Article Orthopedics

Osseodensification drilling vs conventional manual instrumentation technique for posterior lumbar fixation: Ex-vivo mechanical and histomorphological analysis in an ovine model

Andrea Torroni, Paulo Eduardo Lima Parente, Lukasz Witek, Jacques Henri Hacquebord, Paulo G. Coelho

Summary: This study compared R and OD osteotomy instrumentation in posterior lumbar fixation using a sheep model, finding that the OD group showed better mechanical stability, while no significant differences were detected in bone histomorphology analysis.

JOURNAL OF ORTHOPAEDIC RESEARCH (2021)

Article Engineering, Biomedical

Aging resistance of an experimental zirconia-toughened alumina composite for large span dental prostheses: Optical and mechanical characterization

E. B. Benalcazar Jalkh, E. T. P. Bergamo, K. N. Monteiro, P. F. Cesar, L. A. Genova, A. C. O. Lopes, P. N. Lisboa Filho, P. G. Coelho, C. F. Santos, F. Bortolin, M. M. T. Piza, E. A. Bonfante

JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS (2020)

Article Dentistry, Oral Surgery & Medicine

Monolithic CAD/CAM laminate veneers: Reliability and failure modes

Jose Carlos Romanini-Junior, Ronaldo Hirata, Estevam A. Bonfante, Dimorvan Bordin, Rose Yakushijin Kumagai, Vinicius P. Fardin, Paulo G. Coelho, Andre F. Reis

DENTAL MATERIALS (2020)

Article Engineering, Biomedical

Effect of indenter material on reliability of all-ceramic crowns

Fabio C. Lorenzoni, Estevam A. Bonfante, Guilherme B. Valverde, Paulo G. Coelho, Gerson Bonfante, Van P. Thompson, Nelson R. F. A. Silva

JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS (2020)

Article Dentistry, Oral Surgery & Medicine

Assessing osseointegration of metallic implants with boronized surface treatment

Lukasz Witek, Nick Tovar, Christopher D. Lopez, Jonathan Morcos, Michelle Bowers, Roumiana S. Petrova, Paulo G. Coelho

MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL (2020)

Meeting Abstract Medicine, General & Internal

Pachydysostosis of the fibula in a case of Gardner Syndrome - a case report

Daniela Oliveira, Sofia Maia, Ines Balaco, Paulo Coelho, Susana Almeida, Margarida Venancio, Jorge Saraiva, Gen Nishimura, Sergio B. Sousa

MEDICINE (2020)

Article Medicine, General & Internal

A Rare Cause of Optic Neuropathy

Isabel O. Cruz, Sara Alves Pereira, Bruna Vieira, Ines Chora, Paulo Coelho

CUREUS JOURNAL OF MEDICAL SCIENCE (2020)

No Data Available