4.7 Article

Collection of atmospheric gaseous mercury for stable isotope analysis using iodine- and chlorine-impregnated activated carbon traps

Journal

JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY
Volume 29, Issue 5, Pages 841-852

Publisher

ROYAL SOC CHEMISTRY
DOI: 10.1039/c3ja50356a

Keywords

-

Funding

  1. European Research Council MERCURY ISOTOPES project [ERC-2010-StG-20091028]
  2. National Science Foundation of China [41273145]

Ask authors/readers for more resources

The trace levels of Hg in the atmosphere pose an analytical challenge for Hg stable isotope research. Here we propose a new method using iodine- and chlorine-impregnated activated carbon (IC and CLC) traps for collection of atmospheric total gaseous mercury (TGM). Decontamination of IC and CLC yielded low blank levels of 0.3 ng Hg per g of carbon, corresponding to <3% of collected Hg. IC and CLC traps with 250, 600 and 1000 mg of a sorbent collected TGM efficiently (>92%) at flow rates of 2, 10, and 20 LPM respectively. These flow rates enabled high-resolution (12-24 h) and low-resolution (bi-weekly) sampling of TGM. We also tested bi-weekly TGM sampling using commercial gold traps at a low flow rate of 0.3 LPM. TGM collected on IC and CLC traps at the Pic du Midi Observatory was desorbed and pre-concentrated into aqueous solution using an off-line combustion and trapping technique. Hg isotopic compositions were determined using cold vapor multicollector-inductively coupled plasma-mass spectrometry (CV-MC-ICPMS). The field measurements showed mean recoveries of 88 +/- 5% (1 sigma, n = 11) for 12 h and 24 h and 90 +/- 6% (1 sigma, n = 25) for the bi-weekly field samples. Laboratory additions of Hg vapor of known isotopic composition to CLC and gold traps indicated that recoveries >81% did not induce isotopic artifacts. Samples with recoveries <81% showed a positive mass dependent fractionation bias. Typical expanded uncertainties (2 sigma) on delta Hg-202 (mass dependent fractionation of Hg-202) and Delta Hg-199 (mass independent fractionation of Hg-199) for the bi-weekly sampling, processing and CV-MC-ICPMS analysis are 0.13 parts per thousand and 0.09 parts per thousand, respectively. Our study suggests that the proposed method meets the criteria for accurate and precise measurements of atmospheric TGM isotopic compositions.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available