4.7 Article

Polymer monolith microextraction combined with electrothermal vaporization inductively coupled plasma mass spectrometry for the determination of trace Cd, Tl, and Pb in human serum and urine

Journal

JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY
Volume 24, Issue 1, Pages 76-82

Publisher

ROYAL SOC CHEMISTRY
DOI: 10.1039/b810442e

Keywords

-

Funding

  1. NSFC [20621502]
  2. National Nature Science Foundation of China [20575048, 20375030]
  3. National Science Fund for Distinguished Young Scholars [20625516]
  4. MOE of China [NCET-04-0658]

Ask authors/readers for more resources

A novel method of polymer monolith microextraction (PMME) using a poly(acrylamide-vinylpyridine-N,N'-methylene bisacrylamide) (AA-VP-Bis) monolithic column combined with electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS) for the determination of trace Cd, Tl, and Pb with Pd as chemical modifier has been proposed. Several factors that influence the microextraction efficiency including pH value, sample flow rate, extraction time, sample volume, eluent volume, and coexisting ions, were investigated and the optimal microextraction conditions were established. The chemical modification of Pd in ETV-ICP-MS has been studied and the results indicated that the pyrolysis temperature for the target analytes could be increased up to 600 degrees C and the signal intensities were increased by 4.1, 2.1, and 13.8 times for Cd, Tl, and Pb, respectively. Under the optimized conditions, with a consumption of 0.4 mL sample, the limits of detection (LODs) were 1.1, 0.5, and 0.2 ng L-1 for Cd, Tl, and Pb, and the relative standard deviations (RSDs) were 10.3, 9.7, and 9.2% (C 0.05 mu g L-1, n 5) for Cd, Tl, and Pb, respectively. The proposed method was successfully applied to the determination of trace Cd, Tl, and Pb in human serum and urine samples, and the recovery for the spiked samples were in the range of 90-110%. In order to validate the proposed method, certified reference material of GBW09103 human urine was analyzed, and the determined values were in good agreement with the certified values. The poly(AA-VP-Bis) monolith can be used more than 40 times without decrease in the extraction efficiency.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available