4.6 Article

Dynamic response analysis and output voltage control of asymmetric half bridge DC-DC converter for low voltage applications

Journal

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.ijepes.2012.06.038

Keywords

Dynamic response; Half bridge converter; Classic controllers and Genetic Algorithm (GA)

Ask authors/readers for more resources

Asymmetric control scheme is an approach to achieve Zero Voltage Switching (ZVS) for half bridge isolated DC-DC converters. Due to the switching property included in their structure, DC-DC converters have a nonlinear behavior and their controller design is accompanied with complexities. But by employing the average method it is possible to approximate the system into a linear system and then linear control methods can be used. Dynamic performance of half bridge converters output voltage can be controlled by Pole placement and PID controllers. In this paper, Genetic Algorithm is used to optimize the system to achieve the optimum dynamic response. Matrix coefficients and dominant poles of closed loop transfer function is selected based on Genetic Algorithm. The results show an improvement in voltage control response in a short time. Crown Copyright (C) 2012 Published by Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available