Improvement of the fatigue resistance of NiTi endodontic files by surface and bulk modifications

Journal

INTERNATIONAL ENDODONTIC JOURNAL
Volume 43, Issue 10, Pages 866-873

Publisher

WILEY
DOI: 10.1111/j.1365-2591.2010.01759.x

Keywords

electropolishing; fracture mechanism; NiTi instruments; thermal treatment

Ask authors/readers for more resources

P>Aim To assess the failure mechanism of rotary NiTi instruments by chemical, structural and morphological analyses to provide a rational explanation of the effects of surface and bulk treatments on their resistance to fatigue fracture. Methodology Thermal treatment (350-500 degrees C) was performed on electropolished (EP) and non-electropolished (Non-EP) NiTi endodontic instruments. Bulk and surface chemical composition and crystallographic structures were determined by energy-dispersive X-ray spectroscopy, X-ray photoelectron spectroscopy (XPS) and X-ray diffraction (XRD) to evaluate the effects of thermal treatment and electropolishing on the NiTi alloy. Fatigue tests of all instruments were performed. Surface morphology before and after the tests, and fractured section were analysed using scanning electron microscopy to determine crack extensions. Results were analysed statistically using analysis of variance (anova) and post hoc Student-Newman-Keuls test. Results Before thermal treatment, significant differences (P < 0.05) in fatigue resistance between EP and Non-EP instruments (the number of revolutions to failure, N-f, was 385 and 160, respectively) were attributed to differences in the surface morphology of the instruments. SEM analysis of the fracture surfaces indicated that flexural fatigue fractures occurred in two steps: first by a slow growth of initial cracks and then rapid rupture of the remaining material. Thermal treatment did not affect the surface morphology but resulted in significant changes in the instrument bulk with the appearance of an R-phase and an improved fatigue resistance; indeed after treatment at 500 degrees C, N-f increased up to 829 and 474 for EP and Non-EP instruments, respectively. Conclusions Both thermal treatment and electropolishing improved the resistance of NiTi rotary instruments against fatigue fracture.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available