Journal
IEEE TRANSACTIONS ON NUCLEAR SCIENCE
Volume 59, Issue 2, Pages 379-388Publisher
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TNS.2012.2187311
Keywords
High resolution timing detector; scintillator counter; timing counter
Funding
- Grants-in-Aid for Scientific Research [22000004] Funding Source: KAKEN
Ask authors/readers for more resources
The Timing Counter of the MEG (Mu to Electron Gamma) experiment is designed to deliver trigger information and to accurately measure the timing of the e(+) in searching for the decay mu(+) -> e(+)gamma. It is part of a magnetic spectrometer with the mu(+) decay target in the center. It consists of two sectors upstream and downstream the target, each one with two layers: the inner one made with scintillating fibers read out by APDs for trigger and track reconstruction, the outer one consisting in scintillating bars read out by PMTs for trigger and time measurement. The design criteria, the obtained performances and the commissioning of the detector are presented herein.