4.6 Article

Sample entropy analysis for the estimating depth of anaesthesia through human EEG signal at different levels of unconsciousness during surgeries

期刊

PEERJ
卷 6, 期 -, 页码 -

出版社

PEERJ INC
DOI: 10.7717/peerj.4817

关键词

Electroencephalogram; Sample entropy; ANOVA; Depth of anaesthesia; Random Forest

资金

  1. Innovation Center for Big Data and Digital Convergence, Yuan Ze University, Taiwan - Ministry of Education
  2. National Chung-Shan Institute of Science AMP
  3. Technology in Taiwan
  4. Wuhan University of Technology international exchange program [2015-JL-012]
  5. National Natural Science Foundation of China [51475342, 51675389]

向作者/读者索取更多资源

Estimating the depth of anaesthesia (DoA) in operations has always been a challenging issue due to the underlying complexity of the brain mechanisms. Electroencephalogram (EEG) signals are undoubtedly the most widely used signals for measuring DoA. In this paper, a novel EEG -based index is proposed to evaluate DoA for 24 patients receiving general anaesthesia with different levels of unconsciousness. Sample Entropy (SampEn) algorithm was utilised in order to acquire the chaotic features of the signals. After calculating the SampEn from the EEG signals, Random Forest was utilised for developing learning regression models with Bispectral index (BIS) as the target Correlation coefficient, mean absolute error, and area under the curve (AUC) were used to verify the perioperative performance of the proposed method. Validation comparisons with typical nonstationary signal analysis methods (i.e., recurrence analysis and permutation entropy) and regression methods (i.e., neural network and support vector machine) were conducted. To further verify the accuracy and validity of the proposed methodology, the data is divided into four unconsciousness -level groups on the basis of BIS levels. Subsequently, analysis of variance (ANOVA) was applied to the corresponding index (i.e., regression output). Results indicate that the correlation coefficient improved to 0.72 +/- 0.09 after filtering and to 0.90 +/- 0.05 after regression from the initial values of 0.51 +/- 0.17. Similarly, the final mean absolute error dramatically declined to 5.22 +/- 2.12. In addition, the ultimate AUC increased to 0.98 +/- 0.02, and the ANOVA analysis indicates that each of the four groups of different anaesthetic levels demonstrated significant difference from the nearest levels. Furthermore, the Random Forest output was extensively linear in relation to BIS, thus with better DoA prediction accuracy. In conclusion, the proposed method provides a concrete basis for monitoring patients' anaesthetic level during surgeries.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据