4.7 Article

The failure behavior of double-layer metal foam sandwich beams under three-point bending

期刊

THIN-WALLED STRUCTURES
卷 180, 期 -, 页码 -

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.tws.2022.109801

关键词

Double-layer sandwich beams; Metal foam; Failure mode; Failure mechanism map; Minimum mass design

资金

  1. NSFC [11872291]
  2. State Key Laboratory of Automotive Safety and Energy, China [KFY2202]
  3. Fundamental Research Funds for the Central Universities, China [lzujbky-2021-kb03]
  4. opening project of State Key Laboratory of Structural Analysis for Industrial Equipment [GZ20102]

向作者/读者索取更多资源

The failure behavior of double-layer metal foam sandwich beams under three-point bending is investigated experimentally and analytically. Several failure modes are observed, and analytical formulas are provided to predict the critical failure loads.
The failure behavior of the double-layer metal foam sandwich beam under three-point bending is investigated experimentally and analytically. Three main failure modes are observed, i.e. indentation, face yield and core shear A-AB. Also, the combined indentation and face yield, and core shear and indentation are observed, respectively. The analytical formulas are given to predict the critical failure loads of double-layer sandwich beams under different failure modes. Analytical results are in good agreement with the experimental ones. The failure mechanism maps of double-layer sandwich beams are constructed, and the minimum mass design of the double-layer metal foam sandwich beam is presented.