期刊
INDOOR AIR
卷 27, 期 4, 页码 803-815出版社
WILEY
DOI: 10.1111/ina.12357
关键词
contaminant dispersion; human exhalation flow; PIV; velocity and concentration decay
类别
资金
- European Regional Development Fund (ERDF)
Human exhalation flow is a potential source of pathogens that can constitute a cross-infection risk to people in indoor environments. Thus, it is important to investigate the characteristics of this flow, its development, area of influence, and the diffusion of the exhaled contaminants. This paper uses phase-averaged particle image velocimetry together with a tracer gas (CO2) to study two different exhalation flows over time: the exhalation of an average male (test M) and an average female (test F), using a life-sized thermal manikin in a supine position. The exhalation jets generated for both tests are similar in terms of symmetrical geometry, vorticity values, jet opening angles, and velocity and concentration decays. However, there is a difference in the penetration length of the two flows throughout the whole exhalation process. There is also a time difference in reaching maximum velocity between the two tests. It is also possible to see that the tracer gas dispersion depends on the momentum of the jet so the test with the highest velocity decay shows the lowest concentration decay. All these results are of interest to better understand cross-infection risk.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据