4.6 Article

Reductions in particulate matter concentrations resulting from air filtration: A randomized sham-controlled crossover study

期刊

INDOOR AIR
卷 32, 期 2, 页码 -

出版社

WILEY
DOI: 10.1111/ina.12982

关键词

central system filtration; indoor air quality; PM2.5; stand-alone air cleaners; ultrafine particles

资金

  1. California Air Resources Board [11-324]

向作者/读者索取更多资源

The study showed that true high-efficiency air filtration significantly improved indoor air quality, with a 48% reduction in indoor PM0.2 and PM2.5 concentrations and a 31% reduction in PM10. Continuous operation of standalone air cleaners led to greater improvements in particle concentrations. Keeping windows closed and increasing utilization of the filtration systems further enhanced indoor air quality.
One-hundred seventy-two households were recruited from regions with high outdoor air pollution (Fresno and Riverside, CA) to participate in a randomized, sham-controlled, cross-over study to determine the effectiveness of high-efficiency air filtration to reduce indoor particle exposures. In 129 households, stand-alone HEPA air cleaners were placed in a bedroom and in the main living area. In 43 households, high-efficiency MERV 16 filters were installed in central forced-air heating and cooling systems and the participating households were asked to run the system on a clean-air cycle for 15 min per hour. Participating households that completed the study received true air filtration for a year and sham air filtration for a year. Air pollution samples were collected at approximately 6-month intervals, with two measurements in each of the sham and true filtration periods. One week indoor and outdoor time-integrated samples were collected for measurement of PM2.5, PM10, and ultrafine particulate matter (UFP) measured as PM0.2. Reflectance measurements were also made on the PM2.5 filters to estimate black carbon. True filtration significantly improved indoor air quality, with a 48% reduction in the geometric mean indoor PM0.2 and PM2.5 concentrations, and a 31% reduction in PM10. Geometric mean concentrations of indoor/outdoor reflectance values, indicating fraction of particles of outdoor origin remaining indoors, decreased by 77%. Improvements in particle concentrations were greater with continuously operating stand-alone air cleaners than with intermittent central system filtration. Keeping windows closed and increased utilization of the filtration systems further improved indoor air quality.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据