标题
Systematic Review of Current Devices for 24-h Intraocular Pressure Monitoring
作者
关键词
24-h, Contact lens sensor, EYECARE<sup>®</sup> (Implandata Ophthalmic Products GmbH), Glaucoma, Icare<sup>®</sup> tonometer (Icare Finland Oy), Intraocular pressure, Phosphene tonometer, Self-tonometry, Triggerfish<sup>®</sup> (Sensimed AG), Wireless intraocular transducer
出版物
ADVANCES IN THERAPY
Volume 33, Issue 10, Pages 1679-1690
出版商
Springer Nature
发表日期
2016-08-16
DOI
10.1007/s12325-016-0388-4
参考文献
相关参考文献
注意:仅列出部分参考文献,下载原文获取全部文献信息。- Fluctuations of the Intraocular Pressure in Pseudoexfoliation Syndrome and Normal Eyes Measured by a Contact Lens Sensor
- (2016) Naoki Tojo et al. JOURNAL OF GLAUCOMA
- The Effect of Corneal Biomechanical Properties on Rebound Tonometer in Patients With Normal-Tension Glaucoma
- (2015) Jonghoon Shin et al. AMERICAN JOURNAL OF OPHTHALMOLOGY
- Evaluation of a new rebound tonometer for self-measurement of intraocular pressure
- (2015) Priya L Dabasia et al. BRITISH JOURNAL OF OPHTHALMOLOGY
- Preliminary study on implantable inductive-type sensor for continuous monitoring of intraocular pressure
- (2015) Yong Woo Kim et al. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY
- Effect of glaucoma medications on 24-hour intraocular pressure-related patterns using a contact lens sensor
- (2015) Kaweh Mansouri et al. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY
- Implantation of a Novel Telemetric Intraocular Pressure Sensor in Patients With Glaucoma (ARGOS Study): 1-Year Results
- (2015) A. Koutsonas et al. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE
- Clinical Evaluation of the New Rebound Tonometers Icare PRO and Icare ONE Compared With the Goldmann Tonometer
- (2015) Javier Moreno-Montañés et al. JOURNAL OF GLAUCOMA
- Circadian intraocular pressure patterns in healthy subjects, primary open angle and normal tension glaucoma patients with a contact lens sensor
- (2014) Luca Agnifili et al. ACTA OPHTHALMOLOGICA
- Twenty-four-hour intraocular pressure patterns in patients with thyroid eye disease
- (2014) Anjali S Parekh et al. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY
- A wireless intraocular pressure monitoring device with a solder-filled microchannel antenna
- (2014) Çağdaş Varel et al. JOURNAL OF MICROMECHANICS AND MICROENGINEERING
- Twenty-Four-Hour Intraocular Pressure Related Changes Following Adjuvant Selective Laser Trabeculoplasty for Normal Tension Glaucoma
- (2014) Jacky W.Y. Lee et al. MEDICINE
- Global Prevalence of Glaucoma and Projections of Glaucoma Burden through 2040
- (2014) Yih-Chung Tham et al. OPHTHALMOLOGY
- An Implantable Intraocular Pressure Transducer
- (2014) Samir Melki et al. JAMA Ophthalmology
- Assessment of IcareONE rebound tonometer for self-measuring intraocular pressure
- (2013) Mari Sakamoto et al. ACTA OPHTHALMOLOGICA
- Comparison of the new rebound tonometer with Goldmann applanation tonometer in a clinical setting
- (2013) Kyoung Nam Kim et al. ACTA OPHTHALMOLOGICA
- Comparison of Intraocular Pressure Measurements and Assessment of Intraobserver and Interobserver Reproducibility With the Portable ICare Rebound Tonometer and Goldmann Applanation Tonometer in Glaucoma Patients
- (2013) Sarwat Salim et al. JOURNAL OF GLAUCOMA
- Evaluation of Continuous 24-Hour Intraocular Pressure Monitoring for Assessment of Prostaglandin-induced Pressure Reduction in Glaucoma
- (2013) Gábor Holló et al. JOURNAL OF GLAUCOMA
- Comparison of Fluctuations of Intraocular Pressure Before and After Selective Laser Trabeculoplasty in Normal-tension Glaucoma Patients
- (2013) Naoki Tojo et al. JOURNAL OF GLAUCOMA
- Continuous 24-Hour Monitoring of Intraocular Pressure Patterns With a Contact Lens Sensor
- (2012) Kaweh Mansouri et al. ARCHIVES OF OPHTHALMOLOGY
- Meeting an unmet need in glaucoma: continuous 24-h monitoring of intraocular pressure
- (2012) Kaweh Mansouri et al. Expert Review of Medical Devices
- Evaluation of the Icare-ONE rebound tonometer as a self-measuring intraocular pressure device in normal subjects
- (2012) Ioannis Halkiadakis et al. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY
- Monitoring intraocular pressure for 24 h
- (2011) J. H. K. Liu et al. BRITISH JOURNAL OF OPHTHALMOLOGY
- A new rebound tonometer for home monitoring of intraocular pressure
- (2011) André Rosentreter et al. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY
- Precision and accuracy of the ICare tonometer - Peripheral and central IOP measurements by rebound tonometry
- (2010) Danson V. Muttuvelu et al. ACTA OPHTHALMOLOGICA
- A Miniature-Implantable RF-Wireless Active Glaucoma Intraocular Pressure Monitor
- (2010) Eric Y. Chow et al. IEEE Transactions on Biomedical Circuits and Systems
- Evaluation of a Contact Lens-Embedded Sensor for Intraocular Pressure Measurement
- (2010) Michael D. Twa et al. JOURNAL OF GLAUCOMA
- Continuous Monitoring of Intraocular Pressure
- (2009) Arthur J. Sit JOURNAL OF GLAUCOMA
- Self-tonometry in Glaucoma Management—Past, Present and Future
- (2009) Steve Y.-W. Liang et al. SURVEY OF OPHTHALMOLOGY
- Pascal, ICare and Goldmann applanation tonometry - a comparative study
- (2008) Gauti Jóhannesson et al. ACTA OPHTHALMOLOGICA
- Wireless contact lens sensor for intraocular pressure monitoring: assessment on enucleated pig eyes
- (2008) Matteo Leonardi et al. ACTA OPHTHALMOLOGICA
- Correlations Between Corneal Biomechanical Properties Measured With the Ocular Response Analyzer and ICare Rebound Tonometry
- (2008) Jorge Manuel Martins Jorge et al. JOURNAL OF GLAUCOMA
Find the ideal target journal for your manuscript
Explore over 38,000 international journals covering a vast array of academic fields.
SearchCreate your own webinar
Interested in hosting your own webinar? Check the schedule and propose your idea to the Peeref Content Team.
Create Now