期刊
INDOOR AND BUILT ENVIRONMENT
卷 21, 期 1, 页码 150-162出版社
SAGE PUBLICATIONS LTD
DOI: 10.1177/1420326X11423162
关键词
CO2 reduction; Column-beam structure; Green frame; Composite precast concrete
类别
资金
- National Research Foundation of Korea (NRF)
- Korea government (MEST) [2011-0001031]
Over the past 30 years, Korea has adopted structural frames with bearings for apartment buildings. The unit planning flexibility of such a structural system is inadequate, when compared to the column-beam system. The system would allow renovation easily and would provide various other legal benefits to constructors in Korea. For this reason, a column-beam system, named by green frame (GF), implemented with composite precast concrete (PC) members was previously developed. However, since the scheme would require a performance improvement to increase its economic effects and constructability, a further improved system has been developed. In the case of structural construction, it is a construction process that emits the most CO2. Along with the constructability and economic feasibility of a construction system, a reduction in CO2 is also critical. The purpose of this paper was to analyze the CO2-reduction effect of the improved system constructed with enhanced composite PC members. The improved system would greatly contribute to CO2 reduction with an average of 25.0% as compared with the bearing wall structure; and 2.8% compared to the existing GF.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据