4.7 Article

Experimental study of SO2 and NOx emissions in fluidized bed oxy-fuel combustion

期刊

FUEL PROCESSING TECHNOLOGY
卷 106, 期 -, 页码 587-594

出版社

ELSEVIER
DOI: 10.1016/j.fuproc.2012.09.030

关键词

SO2 capture; NOx emissions; Oxy-fuel; Fluidized bed boilers; Coal

资金

  1. R+D Spanish National Program from the Spanish Ministry of Science and Innovation (MICINN, Ministerio de Ciencia e Innovacion) [ENE-2009-08246]
  2. Fundacion CIUDEN

向作者/读者索取更多资源

This paper studies the SO2 and NOx emissions from coal oxy-firing in bubbling fluidized bed combustors. The influence of bed temperature and excess oxygen is measured and discussed. The results are also compared with conventional air combustion, in order to determine whether oxy-firing contributes to increase emission levels. Two completely different coals, Central Europe bituminous and domestic Spanish high-sulfur lignite, have been tested in the CIRCE 90 kW fluidized bed combustor. Although literature data are scarce, a comparison with the findings of the research is fair. Good SO2 capture efficiencies have been reached, even for the lignite tests, pointing towards the direct sulphation of added sorbent-limestone as the dominant mechanism. As for the NOx emissions, significant coupled influences of oxygen and carbon monoxide concentrations are reported. Notwithstanding this, no relevant differences are observed between air- and oxy-firing if NOx emissions are normalized by energy unit. The paper provides clear insights into the effect of operating conditions of oxy-fuel fluidized beds upon SO2 and NOx emissions. (C) 2012 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据