4.5 Article

Postmortem blood concentrations of organophosphorus pesticides

期刊

FORENSIC SCIENCE INTERNATIONAL
卷 184, 期 1-3, 页码 28-31

出版社

ELSEVIER IRELAND LTD
DOI: 10.1016/j.forsciint.2008.11.008

关键词

Organophosphorus pesticides; Postmortem blood; SPE; GC/MS

向作者/读者索取更多资源

Cases involving acute fatalities due to ingestion of organophosphorus pesticides (OPs), such as chlorpyrifos, diazinon, malathion and parathion, are presented. Solid-phase extraction (SPE) and gas chromatography/mass spectrometry (GC/MS) were used for the analysis of OPs in postmortem blood. After extraction with an Oasis HLB (TM) cartridge, the eluent was evaporated to dryness under a nitrogen stream at 35 degrees C, reconstituted with ethanol, and then analyzed by GC/MS. Terbufos was used as an internal standard. Verification procedures, such as the limit of detection, limit of quantification, linearity of the calibration, precision and recovery were performed. Validation data were adequate for analyzing OPs in blood. Chlorpyrifos, diazinon, malathion and parathion were detected in 31 postmortem blood samples. Parathion was the most frequently detected compound among the four pesticides. The mean concentrations of chlorpyrifos, diazinon, malathion and parathion were 0.72, 1.03, 0.82 and 2.90 mg/L, respectively. (c) 2008 Elsevier Ireland Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据