4.2 Article

Quantitative investigation of air gaps entrapped in multilayer thermal protective clothing in low-level radiation at the moisture condition

期刊

FIRE AND MATERIALS
卷 40, 期 2, 页码 179-189

出版社

WILEY-BLACKWELL
DOI: 10.1002/fam.2278

关键词

protective clothing; thermal protective performance; air gap; thermal radiation; firefighting

资金

  1. National Natural Science Foundation of China [51076073, 91024024]
  2. China National Key Basic Research Special Funds Project [2012CB719705]
  3. Tsinghua University Initiative Scientific Research Program [2012THZ02160]

向作者/读者索取更多资源

The effects of air gaps entrapped within the multilayer protective clothing system on the thermal performance were studied during low-level radiation (2-10kW/m(2)). A bench-scale apparatus was designed to produce the liquid droplets and simulate human sweat transferring through the multilayer fabric system. Two air gaps located between the outer shell and the moisture barrier (Gap A) and between the moisture barrier and the thermal liner (Gap B) were used with different gap sizes (0, 2, and 5mm). The thermal resistance analysis for the heat transfer with a multilayer flat wall was used to interpret the effects of air gap. The results show that the total thermal resistance of a multilayer clothing system and the thermal resistances of the two air gaps are linearly related with the level of heat flux. It is also indicated that the air gap position affects the beneficial effect of the gap size. The effect of Gap B to improve the thermal performance is better than that of Gap A. Copyright (c) 2014 John Wiley & Sons, Ltd.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据