4.5 Article

Relationships between increased aqueous outflow facility during washout with the changes in hydrodynamic pattern and morphology in bovine aqueous outflow pathways

期刊

EXPERIMENTAL EYE RESEARCH
卷 89, 期 6, 页码 942-949

出版社

ACADEMIC PRESS LTD- ELSEVIER SCIENCE LTD
DOI: 10.1016/j.exer.2009.08.002

关键词

aqueous humor; outflow facility; outflow resistance; inner wall; JCT; washout; bovine eye; trabecular meshwork; light microscopy; confocal microscopy

资金

  1. Fight For Sight, Inc.
  2. American Optometric Foundation Ezell Fellowship
  3. Boston University School of Medicine [AHAF G2007-013, G2009-018]
  4. Massachusetts Lions Eye Research Fund, Inc.

向作者/读者索取更多资源

Previous studies suggest that the structural correlate for the increased outflow facility (C) during washout in the bovine eye is separation between the inner wall (IW) and underlying juxtacanalicular connective tissue (JCT). However, how these structural changes affect hydrodynamic patterns of outflow during washout has not been studied. We hypothesize that an increase in the outflow facility during washout is associated with an increase in the effective filtration area (EFA) of aqueous outflow, which is regulated by a loss of the connectivity between the IW and JCT. To test this hypothesis, the relationship between C and the hydrodynamic patterns of outflow as well as the morphological changes in JCT and IW during the washout were investigated. Ten bovine eyes were perfused at 15 mmHg with Dulbecco's PBS + 5.5 mM glucose (DPBS) for 30 min to establish stable baseline C. After measuring baseline C, five eyes (short-duration group) were perfused with 0.5 mL DPBS containing 0.002% microspheres (0.5 mu m) to trace the hydrodynamic pattern of outflow. Five other eyes (long-duration group) were perfused for 3 h to elicit a significant washout effect followed by subsequent perfusion of the same volume (0.5 mL) of microspheres to map out the outflow pattern after washout. All eyes were then perfusion-fixed. Anterior segments were sectioned and prepared for confocal and light microscopy. Total length (TL) and filtration length (FL) of the IW were measured in >= 15 images/eye to calculate percent effective filtration length (PEFL = FL/TL) while TL and length exhibiting JCT/IW separation (SL) were measured in >= 13 images/eye to calculate percent separation length (PSL = SL/TL). In long-duration eyes, C increased 170.5 +/- 21.3% (mean +/- SEM, 1.55 +/- 0.24 vs 4.13 +/- 0.55 mu l/min/mmHg, p = 0.001) above baseline. Pre-fixation C (4.13 +/- 0.55 mu l/min/mmHg) in long-duration was 1.6-fold greater than that (2.14 +/- 0.61 mu l/min/mmHg; p = 0.042) in short-duration. A more uniform tracer labeling was observed in the JCT/IW of long-duration eyes compared to short-duration. PEFL was 2.3-fold larger (52.82 +/- 6.06 vs. 22.2 +/- 6.0%; p = 0.007) and PSL was 2.6-fold larger (54.2 +/- 6.0 vs. 20.5 +/- 1.3%; p = 0.004) in long-duration eyes compared to short-duration. Data from all eyes revealed a positive correlation between PEFL and PSL (p = 0.02). Both PEFL and PSL demonstrated significant positive correlations with the relative increase in C due to washout (p <= 0.05). An additional experiment was performed in which unequal volumes of tracer (0.5 and 1.0 mL) were per-fused in paired eyes for both short- and long-duration (N = 2 for each condition) to examine the affect on PEFL No significant change in PEFL was found in eyes perfused with 0.5 and 1.0 mL within the same group. These data support our hypothesis that separations between the IW and JCT result in an increase in the EFA that then influences C. Altogether, these data suggest that outflow hydrodynamics and the tissue structure work together to regulate outflow resistance. (C) 2009 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据