期刊
EUROPEAN RADIOLOGY
卷 20, 期 2, 页码 348-358出版社
SPRINGER
DOI: 10.1007/s00330-009-1553-9
关键词
CT colonography; Faecal tagging; Bowel preparation; Quality assessment; Computer aided detection
The aim of this study was to compare the computed tomographic colonography (CTC) image quality and patient acceptance of three iodine-based faecal tagging bowel preparations in 60 patients undergoing the following regimens: a 2-day regimen of meal-time administration of iodine and phospho-soda (GFPH); a 2-day regimen of meal-time mild laxative, followed by iodine administered 2 h before CTC (SD); and a 2-day regimen of meal-time administration of iodine (GF). Two independent radiologists assessed tagging quality; quantitative measures included the tagged stool density, and computer-aided detection (CAD) false-positive rate. The GFPH and SD regimens provided better subjective quality than GF (p < 0.001). The latter regimen resulted in a higher proportion of insufficiently tagged segments: the measured average stool density was less than 200 HU in 10.7% in all segments vs 3.6% for SD and < 0.5% for GFPH, respectively. Insufficient tagging occurred mostly in the ascending colon and the caecum. The CAD false-positive rate increased following the trend: GFPH < SD < GF (p = 0.00012). GFPH was worse tolerated than SD (p < 0.05). Considering preparation quality alone, GFPH was the best regimen, but SD provided the best balance between bowel preparation quality and patient acceptability.