4.5 Article Proceedings Paper

USAXS and SAXS from cancer-bearing breast tissue samples

期刊

EUROPEAN JOURNAL OF RADIOLOGY
卷 68, 期 3, 页码 S89-S94

出版社

ELSEVIER IRELAND LTD
DOI: 10.1016/j.ejrad.2008.04.039

关键词

X-ray scattering; Analyzer imaging; Bonse-Hart; Breast tissues

向作者/读者索取更多资源

USAXS and SAXS patterns from cancer-bearing human breast tissue samples were recorded at beamline ID02 of the ESRF using a Bonse-Hart camera and a pinhole camera. The samples were classified as being ductal carcinoma, grade 11, and ductal carcinoma in situ, partly invasive. The samples included areas of healthy collagen, invaded collagen, necrotic ducts with calcifications, and adipose tissue. The scattering patterns were analyzed in different ways to separate the scattering contribution and the direct beam from the observed rocking curve (RC) of the analyzer. It was found that USAXS from all tissues was weak, and the effects on the analyzer RC were observed only in the low-intensity tails of the patterns. The intrinsic RC was convolved with different model functions for the impulse response of the sample, and the best fit with experiment was obtained by the Pearson VII function. Significantly different distributions for the Pearson exponent in were obtained in benign and malignant regions of the samples. For a comparison with analyzer-based imaging (ABI) or diffraction enhanced imaging (DEI) a long-slit integration of the patterns was performed, and this emphasized the scattering contribution in the tails of the rocking Curve. (C) 2008 Elsevier Ireland Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据