3.9 Review

Improved Accuracy of Minimally Invasive Transpedicular Screw Placement in the Lumbar Spine With 3-Dimensional Stereotactic Image Guidance A Comparative Meta-Analysis

期刊

JOURNAL OF SPINAL DISORDERS & TECHNIQUES
卷 28, 期 9, 页码 324-329

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/BSD.0000000000000152

关键词

minimally invasive; pedicle screw; neuronavigation; stereotactic; image guidance; lumbar spine

向作者/读者索取更多资源

Study Design: This study compares the accuracy rates of lumbar percutaneous pedicle screw placement (PPSP) using either 2-dimensional (2-D) fluoroscopic guidance or 3-dimensional (3-D) stereotactic navigation in the setting of minimally invasive spine surgery (MISS). This represents the largest single-operator study of its kind and first comprehensive review of 3-D stereotactic navigation in the setting of MISS. Objective: To examine differences in accuracy of lumbar pedicle screw placement using 2-D fluoroscopic navigation and 3-D stereotaxis in the setting of MISS. Summary of Background Data: Surgeons increasingly rely upon advanced image guidance systems to guide minimally invasive PPSP. Three-dimensional stereotactic navigation with intraoperative computed tomography offers well-documented benefit in open surgical approaches. However, the utility of 3-D stereotaxis in the setting of MISS remains incompletely explored by few studies with limited patient numbers. Materials and Methods: A total of 599 consecutive patients underwent minimally invasive lumbar PPSP aided by 3-D stereotactic navigation. Postoperative imaging and medical records were analyzed for patient demographics, incidence and degree of pedicle breach, and other surgical complications. A total of 2132 screw were reviewed and compared with a meta-analysis created from published data regarding the placement of 4248 fluoroscopically navigated pedicle screws in the setting of MISS. Results: In the 3-D navigation group, a total of 7 pedicle breaches occurred in 6 patients, corresponding to a per-person breach rate of 1.15% (6/518) and a per-screw breach rate of 0.33% (7/2132). Meta-analysis comprised of data from 10 independent studies showed overall breach risk of 13.1% when 2-D fluoroscopic navigation was utilized in MISS. This translates to a 99% decrease in odds of breach in the 3-D navigation technique versus the traditional 2-D-guided technique, with an odds ratio of 0.01, (95% confidence interval, 0.01-0.03), P<0.001. Conclusions: Three-dimensional stereotactic navigation based upon intraoperative computed tomography imaging offers markedly improved accuracy of percutaneous lumbar pedicle screw placement when used in the setting of MISS.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

3.9
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据