期刊
ELECTROANALYSIS
卷 24, 期 3, 页码 581-590出版社
WILEY-V C H VERLAG GMBH
DOI: 10.1002/elan.201100540
关键词
Cholinesterase biosensor; Nerve agents; Screen-printed electrodes
资金
- AereoSekur S.p.A, Aprilia, Italy
In a previous work we have developed a biosensor able to detect the Sarin gas at a concentration of 0.1 mg/m3 with only 30 s of incubation time [1]. In this work, we modified the biosensor in order to integrate it into a miniaturized prototype. The prototype is composed of the cell in which is inserted the biosensor, a little fan able to sampling air and an electronic circuit. The circuit is able to apply the potential, to register the current, to turn on-off the fan and eventually give an alarm. The system was tested with paraoxon with satisfactory results.