期刊
DESALINATION AND WATER TREATMENT
卷 44, 期 1-3, 页码 110-117出版社
DESALINATION PUBL
DOI: 10.1080/19443994.2012.691802
关键词
Commercial and analar NaF solutions; Tap water; Electrocoagulation-flotation; Defluoridation; Monopolar; Bipolar
Electrocoagulation-flotation (ECF) process evades many of the defects of chemical processes and considered as a simple low coast one for fluoride removal. The present work deals with defluoridation of different sodium fluoride solutions of both analar (AR) and commercial grades using bipolar and monopolar ECF. The effect of different variables on the defluoridation process; the initial fluoride solution concentration, speed of agitation, number of electrodes and distances between them, volume of solution, time of experiment, presence of additives and coexisting anions were studied. Complete removal is obtained after 5 min for AR grade (5 mg l(-1)) and for commercial (4.93 mg l(-1)) solutions without adding any additives. Monopolar configuration showed more effective removal than the bipolar one. This method is considered as a perfect one in the removal of high concentrations of fluoride in AR and commercial solutions in short time with no environmental risk and can be used in the industrial field. Data was analyzed using statistical programs trying to derive a modeling equation representing the conditions of defluoridation process.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐