4.6 Article

Passive leg-raising and end-expiratory occlusion tests perform better than pulse pressure variation in patients with low respiratory system compliance

期刊

CRITICAL CARE MEDICINE
卷 40, 期 1, 页码 152-157

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/CCM.0b013e31822f08d7

关键词

passive leg raising; pulse pressure variation; volume expansion; volume responsiveness

资金

  1. APHP France

向作者/读者索取更多资源

Objectives: We tested whether the poor ability of pulse pressure variation to predict fluid responsiveness in cases of acute respiratory distress syndrome was related to low lung compliance. We also tested whether the changes in cardiac index induced by passive leg-raising and by an end-expiratory occlusion test were better than pulse pressure variation at predicting fluid responsiveness in acute respiratory distress syndrome patients. Design: Prospective study. Setting: Medical intensive care unit. Patients: We included 54 patients with circulatory shock (63 +/- 13 yrs; Simplified Acute Physiology Score II, 63 +/- 24). Twenty-seven patients had acute respiratory distress syndrome (compliance of the respiratory system, 22 +/- 3 mL/cm H2O). In nonacute respiratory distress syndrome patients, the compliance of the respiratory system was 45 +/- 9 mL/cm H2O. Measurements and Main Results: We measured the response of cardiac index (transpulmonary thermodilution) to fluid administration (500 mL saline). Before fluid administration, we recorded pulse pressure variation and the changes in pulse contour analysis-derived cardiac index induced by passive leg-raising and end-expiratory occlusion. Fluid increased cardiac index >= 15% (44% +/- 39%) in 30 responders. Pulse pressure variation was significantly correlated with compliance of the respiratory system (r = .58), but not with tidal volume. The higher the compliance of the respiratory system, the better the prediction of fluid responsiveness by pulse pressure variation. A compliance of the respiratory system of 30 mL/cm H2O was the best cut-off for discriminating patients regarding the ability of pulse pressure variation to predict fluid responsiveness. If compliance of the respiratory system was >30 mL/cm H2O, then the area under the receiver-operating characteristics curve for predicting fluid responsiveness was not different for pulse pressure variation and the passive leg-raising and end-expiratory occlusion tests (0.98 +/- 0.03, 0.91 +/- 0.06, and 0.97 +/- 0.03, respectively). By contrast, if compliance of the respiratory system was <= 30 mL/cm H2O, then the area under the receiver-operating characteristics curve was significantly lower for pulse pressure variation than for the passive leg-raising and end-expiratory occlusion tests (0.69 +/- 0.10, 0.94 +/- 0.05, and 0.93 +/- 0.05, respectively). Conclusions: The ability of pulse pressure variation to predict fluid responsiveness was inversely related to compliance of the respiratory system. If compliance of the respiratory system was <= 30 mL/cm H2O, then pulse pressure variation became less accurate for predicting fluid responsiveness. However, the passive leg-raising and end-expiratory occlusion tests remained valuable in such cases. (Crit Care Med 2012; 40:152-157)

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据