Reasons why dynamic compression plates are inferior to locking plates in osteoporotic bone: a finite element explanation
出版年份 2014 全文链接
标题
Reasons why dynamic compression plates are inferior to locking plates in osteoporotic bone: a finite element explanation
作者
关键词
-
出版物
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING
Volume 18, Issue 16, Pages 1818-1825
出版商
Informa UK Limited
发表日期
2014-12-05
DOI
10.1080/10255842.2014.974580
参考文献
相关参考文献
注意:仅列出部分参考文献,下载原文获取全部文献信息。- Bone properties affect loosening of half-pin external fixators at the pin–bone interface
- (2012) Finn E. Donaldson et al. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED
- Patient-specific modelling of bone and bone-implant systems: the challenges
- (2012) Pankaj Pankaj International Journal for Numerical Methods in Biomedical Engineering
- Cortical bone failure mechanisms during screw pullout
- (2012) Emer M. Feerick et al. JOURNAL OF BIOMECHANICS
- Does screw–bone interface modelling matter in finite element analyses?
- (2012) Alisdair R. MacLeod et al. JOURNAL OF BIOMECHANICS
- Can DCP and LCP plates generate more compression? The effect of multiple eccentrically placed screws and their drill positioning guides
- (2011) Feras M.M. Ya’ish et al. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED
- Investigation of factors affecting loosening of ilizarov ring-wire external fixator systems at the bone-wire interface
- (2011) Finn E. Donaldson et al. JOURNAL OF ORTHOPAEDIC RESEARCH
- Finite element modelling of a unilateral fixator for bone reconstruction: Importance of contact settings
- (2010) Kavin Karunratanakul et al. MEDICAL ENGINEERING & PHYSICS
- Biomechanical evaluation of a new system to improve screw fixation in osteoporotic bones
- (2010) A. Yánez et al. MEDICAL ENGINEERING & PHYSICS
- Effects of the bone-plate material and the presence of a gap between the fractured bone and plate on the predicted stresses at the fractured bone
- (2010) H. Fouad MEDICAL ENGINEERING & PHYSICS
- The effects of screw orientation in severely osteoporotic bone: A comparison with locked plating
- (2009) Scott Zehnder et al. CLINICAL BIOMECHANICS
- The finite element analysis of a fractured tibia applied by composite bone plates considering contact conditions and time-varying properties of curing tissues
- (2009) Suk-Hun Kim et al. COMPOSITE STRUCTURES
- A Nonlocking End Screw Can Decrease Fracture Risk Caused by Locked Plating in the Osteoporotic Diaphysis
- (2009) Michael Bottlang et al. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME
- Predicting time-dependent remodeling of bone around immediately loaded dental implants with different designs
- (2009) Atilim Eser et al. MEDICAL ENGINEERING & PHYSICS
- Evaluation of bone plate with low-stiffness material in terms of stress distribution
- (2008) Semih Benli et al. JOURNAL OF BIOMECHANICS