4.5 Article

Biofluid Activated Microbattery for Disposable Microsystems

期刊

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/JMEMS.2014.2317177

关键词

Battery; microbattery; microelectromechanical systems (MEMS); disposable; biomedical; bodily fluids

资金

  1. Nanoscale Research Facility
  2. Integrated Circuits Research Laboratory

向作者/读者索取更多资源

A flexible aluminum-silver oxide microbattery activated by a liquid electrolyte for on-demand operation is presented. Four different electrolytes are tested: 1) aqueous sodium hydroxide; 2) blood; 3) urine; and 4) saliva. To start the operation of the microbattery 8 mu L of the target electrolyte is pipetted onto the surface of the microbattery. The microbattery is fabricated on a polyimide substrate using conventional microfabrication techniques. The proposed microbatteries have an interdigitated electrode geometry and a minimum footprint area of 12 mm(2). Seven different batteries designs having different electrode width and spacing have been fabricated and characterized. The experimental results show energy densities up to 26.6 mu W h cm(-2)mu m(-1), maximum voltage output of 1.75 V, maximum current output of 0.55 mA, maximum capacity of 7.17 mu Ah, and maximum operating time of 75 min. [2013-0389]

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据