4.3 Article

MALDI-TOF mass spectrometry for rapid identification of clinical fungal isolates based on ribosomal protein biomarkers

期刊

JOURNAL OF MICROBIOLOGICAL METHODS
卷 109, 期 -, 页码 93-105

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.mimet.2014.12.014

关键词

Matrix assisted laser desorption ionization-time of flight mass spectrometry; Fungal isolates; Rapid Identification

资金

  1. All India Institute of Medical Sciences (AIIMS), New Delhi, India

向作者/读者索取更多资源

This study aimed to evaluate the identification of clinical fungal isolates (yeast and molds) by protein profiling using Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF/MS). A total of 125 clinical fungal culture isolates (yeast and filamentous fungi) were collected. The test set included 88 yeast isolates (Candida albicans, Candida glabrata, Candida guilliermondii, Candida kefyr, Candida krusei, Candida parapsilosis, Candida rugosa, Candida tropicalis and Cryptococcus neoformans) and 37 isolates of molds (Alternaria spp., Aspergillus flavus, Aspergillus fumigatus, Aspergillus niger, Cunninghamella spp., Histoplasma capsulatum, Microsporum gypseum, Microsporum nanum, Rhizomucor spp. and Trichophyton spp.). The correlation between MALDI TOF MS and conventional identification for all these 125 fungal isolates included in the study was 87.2% at the species level and 90.4% at the genus level. MALDITOF MS results revealed that the correlation in yeast (n = 88) identification was 100% both at the genus and species levels whereas, the correlation in mold (n = 37) identification was more heterogeneous i.e. 10.81% isolates had correct identification up to the genus level, 56.7% isolates had correct identification both at the genus and species levels, whereas 32.42% isolates were deemed Not Reliable Identification (NRI). But, with the modification in sample preparation protocol for molds, there was a significant improvement in identification. 86.4% isolates had correct identification till the genus and species levels whereas, only 2.7% isolates had Not Reliable Identification. In conclusion, this study demonstrates that MALDITOF MS could be a possible alternative to conventional techniques both for the identification and differentiation of clinical fungal isolates. However, the main limitation of this technique is that MS identification could be more precise only if the reference spectrum of the fungal species is available in the database. (C) 2014 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据