4.8 Article

Temporal Trends in Quality of Care Among Recipients of Implantable Cardioverter-Defibrillators Insights From the National Cardiovascular Data Registry

期刊

CIRCULATION
卷 129, 期 5, 页码 580-586

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1161/CIRCULATIONAHA.113.003747

关键词

cardioverter-defibrillators; implantable; electrophysiology; quality of health care; registries

资金

  1. American College of Cardiology Foundation's NCDR
  2. National Institutes of Health/National Heart, Lung, and Blood Institute in Bethesda, MD [U01 HL105270-02]
  3. Center for Cardiovascular Outcomes Research at Yale University
  4. National Institutes of Health/National Institute on Aging [T32 AG000158-24]
  5. National Institutes of Health/National Heart, Lung, and Blood Institute

向作者/读者索取更多资源

Background The ICD Registry was established in 2006 in part to measure quality of care in patients undergoing implantation of implantable cardioverter-defibrillators (ICDs); however, whether outcomes have improved since initiation of the registry is unknown. Our objective was to examine changes over time in 3 quality metrics available from the registry. Methods and Results We performed an observational study of 367 153 patients who received new ICD implants from April 2006 to March 2010. Three quality metrics were selected: Adverse events (in-hospital complications or mortality), optimal medical therapy (OMT), and cardiac resynchronization therapy (CRT). OMT was defined as prescription of -blocker and either angiotensin-converting enzyme inhibitor or angiotensin receptor blocker in eligible patients. CRT eligibility was determined by QRS 120 ms, left ventricular ejection fraction 35%, and New York Heart Association class III/IV. Observation periods were divided into four 12-month intervals. We analyzed changes over time and used hierarchical logistic regression to adjust for potential confounders. Adverse events decreased over time (3.7% to 2.8%, P<0.001). Among eligible patients, rates of OMT and CRT increased over time (OMT: 69.0% to 74.3%, P<0.001; CRT: 80.5% to 84.2%, P<0.001). After adjustment for potential confounders, patients were significantly less likely to experience adverse events in year 4 than in year 1 (odds ratio, 0.75; 95% confidence interval, 0.71-0.79) and significantly more likely to receive OMT (odds ratio, 1.29; 95% confidence interval, 1.26-1.32) and CRT (odds ratio, 1.42; 95% confidence interval, 1.35-1.49). Conclusions Since initiation of the ICD Registry, adverse events have been decreasing, and rates of OMT and CRT among eligible patients have been increasing, although there is still significant room for improvement.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据