4.5 Article

Calibration and Limits of Camera-Based Fluorescence Correlation Spectroscopy: A Supported Lipid Bilayer Study

期刊

CHEMPHYSCHEM
卷 13, 期 11, 页码 2784-2794

出版社

WILEY-V C H VERLAG GMBH
DOI: 10.1002/cphc.201200032

关键词

fluorescence spectroscopy; membrane; multiplexing; point spread function; total internal reflection

资金

  1. National University of Singapore
  2. Singapore-MIT Alliance
  3. experience@singapore
  4. Ministry of Education of Singapore [MOE2009-T2-2-019]
  5. Life Sciences Institute (NUS)-Baden-Wrttemberg initiative [R-143-000-422-646]

向作者/读者索取更多资源

Camera-based fluorescence correlation spectroscopy (FCS) approaches allow the measurement of thousands of contiguous points yielding excellent statistics and details of sample structure. Imaging total internal reflection FCS (ITIR-FCS) provides these measurements on lipid membranes. Herein, we determine the influence of the point spread function (PSF) of the optical system, the laser power used, and the time resolution of the camera on the accuracy of diffusion coefficient and concentration measurements. We demonstrate that the PSF can be accurately determined by ITIR-FCS and that the laser power and time resolution can be varied over a wide range with limited influence on the measurement of the diffusion coefficient whereas the concentration measurements are sensitive to changes in the measurement parameters. One advantage of ITIR-FCS is that the measurement of the PSF has to be performed only once for a given optical setup, in contrast to confocal FCS in which calibrations have to be performed at least once per measurement day. Using optimized experimental conditions we provide diffusion coefficients for over ten different lipid membranes consisting of one, two and three constituents, measured in over 200000 individual correlation functions. Using software binning and thus the inherent advantage of ITIR-FCS of providing multiple observation areas in a single measurement we test the FCS diffusion law and show how they can be complemented by the local information provided by the difference in cross-correlation functions (?CCF). With the determination of the PSF by ITIR-FCS and the optimization of measurement conditions ITIR-FCS becomes a calibration-free method. This allows us to provide measurements of absolute diffusion coefficients for bilayers with different compositions, which were stable over many different bilayer preparations over a time of at least one year, using a single PSF calibration.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据