4.3 Article

Simple and rapid UV spectrophotometry of caffeine in tea coupled with sample pre-treatment using a cartridge column filled with polyvinylpolypyrrolidone (PVPP)

期刊

CHEMICAL & PHARMACEUTICAL BULLETIN
卷 56, 期 2, 页码 185-188

出版社

PHARMACEUTICAL SOC JAPAN
DOI: 10.1248/cpb.56.185

关键词

tea; caffeine; polyphenol; polyvinylpolypyrrolidone; spectrophotometry; UV

向作者/读者索取更多资源

We have applied a sample pre-treatment method with a cartridge column filled with polyvinylpolypyrrolidone (PVPP) to the effective removal of polyphenols and simple UV spectrophotometry of caffeine in tea. The absorption maximum length (lambda(max)) for caffeine was close to those for tea catechins in aqueous 1% acetic acid; therefore, the UV spectrum of a non-treated green tea sample had a large absorption wave. In contrast, the absorbance of the green tea sample was gradually reduced by PVPP cartridge treatment using PVPP from 0 to 50 mg, and was nearly constant using a pre-treatment cartridge with more than 100 mg PVPP, because tea catechins were effectively removed and caffeine was mostly recovered from a green tea sample by means of PVPP cartridge treatment. The PVPP pre-treatment cartridge also removed polyphenols successfully from oolong and black tea samples. Comparison with conventional HPLC analysis indicated that the present pre-treatment method with a PVPP cartridge was useful for the simple and selective UV spectrophotometric determination of caffeine in green, oolong and black tea samples.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据