4.4 Article

The use of Biobrane® as a delivery method for cultured epithelial autograft in burn patients

期刊

BURNS
卷 39, 期 5, 页码 876-880

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.burns.2012.11.013

关键词

Burns; Biobrane; CEA; Cultured epithelial autograft

向作者/读者索取更多资源

Background: Cultured epithelial autografts (CEA) are well described in the literature and are advantageous when dealing with major burns. There have been many methods of CEA application described, however they all have their own difficulties. Here we describe a novel technique of culturing the keratinocytes in Biobrane (R). Methods: Skin samples were taken from three patients and cultured into pre-confluent keratinocytes. These were seeded in Biobrane (R) and applied directly to the patients' wounds. Results: Three patients had Biobrane (R) with seeded keratinocytes applied. The Biobrane was applied to both donor and burn wound sites, with healing times being similar to the keratinocyte sheets. Conclusion: The experience of the authors shows that using Biobrane (R) seeded with keratinocytes was easier to handle and quicker to produce than confluent sheets of keratinocytes, with no perceived disadvantages to the patients. (C) 2012 Elsevier Ltd and ISBI. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据