4.6 Article

MicroCT morphometry analysis of mouse cancellous bone: Intra- and inter-system reproducibility

期刊

BONE
卷 49, 期 3, 页码 580-587

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.bone.2011.05.013

关键词

Mouse cancellous bone; Bone morphometry; Microcomputed tomography; Reproducibility; Repeatability

资金

  1. NIH [P30-AR046121, R01-DE04141, R01-AG028664, S10-RR024547]
  2. National Center for Research Resources, National Institutes of Health [C06-RR12538]

向作者/读者索取更多资源

The agreement between measurements and the relative performance reproducibility among different microcomputed tomography (microCT) systems, especially at voxel sizes close to the limit of the instruments, is not known. To compare this reproducibility 3D morphometric analyses of mouse cancellous bone from distal femoral epiphyses were performed using three different ex vivo microCT systems: GE eXplore Locus SP, Scanco mu CT35 and Skyscan 1172. Scans were completed in triplicate at 12 mu m and 8 mu m voxel sizes and morphometry measurements, from which relative values and dependence on voxel size were examined. Global and individual visually assessed thresholds were compared. Variability from repeated scans at 12 mu m voxel size was also examined. Bone volume fraction and trabecular separation values were similar, while values for relative bone surface, trabecular thickness and number varied significantly across the three systems. The greatest differences were measured in trabecular thickness (up to 236%) and number (up to 218%). The relative dependence of measurements on voxel size was highly variable for the trabecular number (from 0% to 20% relative difference between measurements from 12 mu m and 8 mu m voxel size scans, depending on the system). The intra-system reproducibility of all trabecular measurements was also highly variable across the systems and improved for BV/TV in all the systems when a smaller voxel size was used. It improved using a smaller voxel size in all the other parameters examined for the Scanco system, but not consistently so for the GE or the Skyscan system. Our results indicate trabecular morphometry measurements should not be directly compared across microCT systems. In addition, the conditions, including voxel size, for trabecular morphometry studies in mouse bone should be chosen based on the specific microCT system and the measurements of main interest. (C) 2011 Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据