4.8 Article

Size-tunable Pt nanoparticles assembled on functionalized ordered mesoporous carbon for the simultaneous and on-line detection of glucose and L-lactate in brain microdialysate

期刊

BIOSENSORS & BIOELECTRONICS
卷 41, 期 -, 页码 511-518

出版社

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2012.09.055

关键词

On-line microdialysis system; Pt/PDDA-CMM hybrid nanocomposite; Glucose; L-lactate; In vivo

资金

  1. National Natural Science Foundation of China [21175044, 21205102]
  2. Science 82 Technology Commission of Shanghai Municipality [10JC1404000, 10JC1411200]
  3. Research Fund for the Doctoral Program of Higher Education [20100076110002]
  4. Ministry Reward for Excellent Doctors in Academics [MXRZZ2011008]

向作者/读者索取更多资源

This study presents a facile electrochemical method for simultaneous and selective on-line detection of glucose and L-lactate in the striatum of anesthetic rats through the integration of selective electrochemical detection with in vivo microdialysis system. A positively-charged polyelectrolyte, (diallyldimethylammonium chloride) (PDDA), was attached onto carbon mesoporous material (CMM) through non-covalent interaction, which provided an ideal environment for the assembling and dispersion of nanoparticle electrocatalysts. Platinum nanoparticles with wide loadings from 5 to 50 wt% were successfully self-assembled on PDDA-functionalized CMM via electrostatic interaction. TEM results showed that with the increase in the Pt loadings, both the size and interconnectivity between particles increased, with particle sizes ranging from 3.2 +/- 0.4 to 6.8 +/- 1.4 nm. Moreover, the electrocatalytic activities of the as-prepared six Pt/PDDA-CMM hybrid nanocomposites were also observed to show an inverted-V-shaped profile as a function of loading amount of Pt NPs. Integrated with glucose oxidase (GOx), L-lactate oxidase (LCD) and the in vivo microdialysis system, the constructed dual oxidase/Pt/PDDA-CMM/Nafion biosensors were successfully applied for the simultaneous and on-line detection of glucose and L-lactate. After post-calibration, the basal level of glucose and L-lactate in the striatum of anesthetic rats was calculated to be 0.27 +/- 0.03 and 0.71 +/- 0.05 mM (mean +/- s.d., n=3), respectively. What is more important, the dual oxidase biosensors almost suffered from little cross-talk, which is characteristic of an excellent sensor with high performance. This property, along with the good linearity and a high stability substantially enables this method promising application in physiology and pathology. (C) 2012 Published by Elsevier B.V.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据