期刊
BIOSENSORS & BIOELECTRONICS
卷 35, 期 1, 页码 258-264出版社
ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2012.02.058
关键词
DNA sensor; Conducting polymer; PEDOT; Nanowire; Scanning ion conductance microscopy
类别
资金
- University of Auckland
- MacDiarmid Institute for Advanced Materials and Nanotechnology, New Zealand
A prerequisite for exploiting sensing devices based on semiconductor nanowires is ultra-sensitive and selective direct electrical detection of biological and chemical species. Here, we constructed a transducer based on copolymer of poly(3,4,-ethylenedioxythiophene) (PEDOT) and carboxylic group functionalised PEDOT single nanowire in between gold electrodes, followed by covalent attachment of amino-modified probe oligonucleotide. The target ODNs specific to Homo sapiens Breast and ovarian cancer cells were detected at femtomolar concentration and incorporation of negative controls (non-complementary ODN) were clearly discriminated by the sensor. The ex situ measurements were performed by using two terminal device setup and the changes in the interface of the nanowire associated with the association or dissociation of ODNs were measured as change in resistance. In addition, in situ measurements were performed by utilizing scanning ion conductance microscopy to measure the change in resistance of probe modified nanowire upon addition of different concentration of target ODNs in presence of relevant buffer. The constructed, nano sensor showed highly sensitive concentration dependent resistance change. (C) 2012 Elsevier B.V. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐