4.5 Article

Unconstrained snoring detection using a smartphone during ordinary sleep

期刊

BIOMEDICAL ENGINEERING ONLINE
卷 13, 期 -, 页码 -

出版社

BIOMED CENTRAL LTD
DOI: 10.1186/1475-925X-13-116

关键词

Sleep management; Sleep disorder; Snoring detection; Formant analysis

资金

  1. MSIP(Ministry of Science, ICT&Future Planning), Korea, under the C-ITRC(Convergence Information Technology Research Center) support program [NIPA-2014-H0401-14-1022]
  2. Ministry of Public Safety & Security (MPSS), Republic of Korea [H0401-14-1022] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)
  3. National Research Foundation of Korea [31Z20130012999] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

向作者/读者索取更多资源

Background: Snoring can be a representative symptom of a sleep disorder, and thus snoring detection is quite important to improving the quality of an individual's daily life. The purpose of this research is to develop an unconstrained snoring detection technique that can be integrated into a smartphone application. In contrast with previous studies, we developed a practical technique for snoring detection during ordinary sleep by using the built-in sound recording system of a smartphone, and the recording was carried out in a standard private bedroom. Method: The experimental protocol was designed to include a variety of actions that frequently produce noise (including coughing, playing music, talking, rining an alarm, opening/closing doors, running a fan, playing the radio, and walking) in order to accurately recreate the actual circumstances during sleep. The sound data were recorded for 10 individuals during actual sleep. In total, 44 snoring data sets and 75 noise datasets were acquired. The algorithm uses formant analysis to examine sound features according to the frequency and magnitude. Then, a quadratic classifier is used to distinguish snoring from non-snoring noises. Ten-fold cross validation was used to evaluate the developed snoring detection methods, and validation was repeated 100 times randomly to improve statistical effectiveness. Results: The overall results showed that the proposed method is competitive with those from previous research. The proposed method presented 95.07% accuracy, 98.58% sensitivity, 94.62% specificity, and 70.38% positive predictivity. Conclusion: Though there was a relatively high false positive rate, the results show the possibility for ubiquitous personal snoring detection through a smartphone application that takes into account data from normally occurring noises without training using preexisting data.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据