4.5 Article

Numerical studies on alternative therapies for femoral head necrosis

期刊

BIOMECHANICS AND MODELING IN MECHANOBIOLOGY
卷 10, 期 5, 页码 627-640

出版社

SPRINGER HEIDELBERG
DOI: 10.1007/s10237-010-0261-3

关键词

Osteonecrosis; Femoral head necrosis; Porous tantalum implant; Core decompression; Finite element simulation; Subtrochanteric fracture risk

向作者/读者索取更多资源

Numerical investigations with regard to the subtrochanteric fracture risk induced by three alternative methods for the treatment of femoral head necrosis are outlined in this presentation. The traditional core decompression technique will be compared with minimal invasive multiple low diameter drillings and the implantation of an innovative tantalum implant. With emphasis to the newly introduced computational strategies and modeling approaches, the modeling of critical loading conditions as well as mesh convergence is outlined in detail. In addition to the immediate postoperative fracture risk, the long-term stability of the different approaches for treating femoral head necrosis is predicted by performing well-established bone remodeling simulation techniques. The computed results are augmented for results obtained from clinical experience.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据