4.7 Article

A novel method for the rapid determination of polyethoxylated tallow amine surfactants in water and sediment using large volume injection with high performance liquid chromatography and tandem mass spectrometry

期刊

ANALYTICA CHIMICA ACTA
卷 889, 期 -, 页码 147-155

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.aca.2015.06.046

关键词

Polyethoxylated tallow amines; Glyphosate surfactants; Water; Sediment; High-performance liquid chromatography-tandem mass spectrometry; Large volume injection

向作者/读者索取更多资源

Polyethoxylated tallow amine (POEA) surfactants have been used in many glyphosate-based herbicide formulations for agricultural, industrial and residential weed control. The potential for release of these compounds into the environment is of increasing concern due to their toxicity towards aquatic organisms. Current methods for analysis of POEA surfactants require significant time and effort to achieve limits of quantification that are often higher than the concentrations at which biological effects have been observed (as low as 2 ng mL(-1)). We have developed a rapid and robust method for quantifying the POEA surfactant mixture MON 0818 at biologically relevant concentrations in fresh water, sea water and lake sediment using reversed phase high-performance liquid chromatography and electrospray ionization-tandem mass spectrometry. Water samples preserved by 1:1 v/v dilution with methanol are analyzed directly following centrifugation. Sediment samples undergo accelerated solvent extraction in aqueous methanol prior to analysis. Large volume (100 mu L) sample injection and multiple reaction monitoring of a subset of the most abundant POEA homologs provide limits of quantification of 0.5 and 2.9 ng mL(-1) for MON 0818 in fresh water and sea water, respectively, and 2.5 ng g(-1) for total MON 0818 in lake sediment. Average recoveries of 93 and 75% were achieved for samples of water and sediment, respectively spiked with known amounts of MON 0818. Precision and accuracy for the analysis of water and sediment samples were within 10 and 16%, respectively based upon replicate analyses of calibration standards and representative samples. Results demonstrate the utility of the method for quantifying undegraded MON 0818 in water and sediment, although a more comprehensive method may be needed to identify and determine other POEA mixtures and degradation profiles that might occur in the environment. Crown Copyright (C) 2015 Published by Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据