4.3 Article

Assessing individual performance and maintaining breath sample integrity in biomedical detection dogs

期刊

BEHAVIOURAL PROCESSES
卷 155, 期 -, 页码 8-18

出版社

ELSEVIER
DOI: 10.1016/j.beproc.2017.08.008

关键词

Canine olfaction; Silicone oil; Breath samples; Sample storage; Breath volatiles; Volatile organic compounds; Olfactory detection

资金

  1. IWK Health Centre Category A Research Grant
  2. NSERC PGS-D

向作者/读者索取更多资源

In empirical tests of biomedical detection dogs, exhaled breath samples are often used because breath contains volatile organic compounds that can signal metabolic states, infection, or disease. However, in studies that present dogs with breath samples, results show a notable degree of variability both between and within studies. Differing protocols for the collection and storage of exhaled breath samples may contribute to this observed variability. The goal of the current study was therefore to test whether there was a difference in the detectability of breath samples collected using silicone-coated versus uncoated cotton balls. This was tested in two experiments. In the first experiment, breath samples were prepared using both silicone-coated and uncoated cotton balls, which were then left exposed to the surrounding air. Four dogs' detection of the samples was tested using a cued, three alternative forced choice (3AFC) procedure at regular intervals up to two hours after the samples were prepared. The results of Experiment 1 showed that the dogs' performance was above chance and there was no significant difference in the dogs' detection of the breath samples across conditions. In the second experiment, a series of breath samples were prepared and stored for one, two, three, and four week periods. The same four dogs' ability to detect the breath samples was tested each week using the same cued 3AFC procedure. The results of Experiment 2 showed that when silicone-coated cotton balls were used, all four dogs could detect the breath samples at above chance levels after the samples were stored for three weeks, and two dogs could detect the samples that were stored for four weeks. When the dogs were tested on their ability to detect the breath samples prepared using uncoated cotton, two dogs' performance fell to below chance levels at one week of storage time, while the other two dogs could detect the breath samples at above chance levels after the samples were stored for four weeks. Taken together, the results of the two experiments illustrate that silicone-coated cotton balls do not improve detectability of breath samples within two hours, but can greatly improve the detectability of breath samples stored over longer periods of time. Since the use of silicone-coated cotton balls only improved the detectability of the breath samples for two of the four dogs, these results highlight the importance of examining individual differences in dogs' performance. Furthermore, we argue that, given the inherent differences in olfactory ability across dogs, widespread use of silicone-coated cotton balls for the collection of breath samples would increase the pool of testable dogs for biomedical detection studies and would decrease the degree of variability both within and between studies.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据