4.3 Article

An Assessment of the Precision and Confidence of Aquatic Eddy Correlation Measurements

期刊

出版社

AMER METEOROLOGICAL SOC
DOI: 10.1175/JTECH-D-14-00089.1

关键词

-

资金

  1. Max Planck Society
  2. EU Seventh Framework Programme SENSEnet [PITN-GA-2009-237868]
  3. Helmholtz Alliance ROBEX
  4. EU project HYPOX [226213]
  5. Netherlands Organisation for Scientific Research (NWO-VIDI) [864.08.004]
  6. Research Foundation-Flanders (FWO-Odysseus) [G.0929.08]
  7. University of Landau
  8. Department of Biology at Southern Danish University
  9. Nordic Center for Earth Evolution (NordCEE) [DNRF 53]
  10. Natural Environment Research Council [NE/F012691/1] Funding Source: researchfish
  11. NERC [NE/F012691/1] Funding Source: UKRI

向作者/读者索取更多资源

The quantification of benthic fluxes with the aquatic eddy correlation (EC) technique is based on simultaneous measurement of the current velocity and a targeted bottom water parameter (e. g., O-2, temperature). High-frequency measurements (64Hz) are performed at a single point above the seafloor using an acoustic Doppler velocimeter (ADV) and a fast-responding sensor. The advantages of aquatic EC technique are that 1) it is noninvasive, 2) it integrates fluxes over a large area, and 3) it accounts for in situ hydrodynamics. The aquatic EC has gained acceptance as a powerful technique; however, an accurate assessment of the errors introduced by the spatial alignment of velocity and water constituent measurements and by their different response times is still needed. Here, this paper discusses uncertainties and biases in the data treatment based on oxygen EC flux measurements in a large-scale flume facility with well-constrained hydrodynamics. These observations are used to review data processing procedures and to recommend improved deployment methods, thus improving the precision, reliability, and confidence of EC measurements. Specifically, this study demonstrates that 1) the alignment of the time series based on maximum cross correlation improved the precision of EC flux estimations; 2) an oxygen sensor with a response time of <0.4 s facilitates accurate EC fluxes estimates in turbulence regimes corresponding to horizontal velocities <11 cm s(-1); and 3) the smallest possible distance (<1 cm) between the oxygen sensor and the ADV's sampling volume is important for accurate EC flux estimates, especially when the flow direction is perpendicular to the sensor's orientation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据