4.6 Article

Minimal Detectable Changes of the Berg Balance Scale, Fugl-Meyer Assessment Scale, Timed Up & Go Test, Gait Speeds, and 2-Minute Walk Test in Individuals With Chronic Stroke With Different Degrees of Ankle Plantarflexor Tone

期刊

出版社

W B SAUNDERS CO-ELSEVIER INC
DOI: 10.1016/j.apmr.2012.01.014

关键词

Cerebrovascular accident; Leg; Movement; Muscle hypertonia; Outcomes assessment (health care); Rehabilitation

向作者/读者索取更多资源

Hiengkaew V. Jitaree K, Chaiyawat P. Minimal detectable changes of the Berg Balance Scale, Fugl-Meyer Assessment Scale, Timed Up & Go Test, gait speeds, and 2-minute walk test in individuals with chronic stroke with different degrees of ankle plantarflexor tone. Arch Phys Med Rehabil 2012;93:1201-8. Objective: To determine test-retest reliability and absolute and relative minimal detectable changes at the 95% confidence level (MDC95) of measures to detect postural balance and lower limb movements in individuals with chronic stroke who were able to walk and had differences in ankle plantarflexor tone. Design: Test-retest study. Data were collected on 2 occasions, about 6 days apart. Setting: Outpatient physical therapy clinics. Participants: Volunteers (N=61) with chronic stroke who were able to walk and had differences in ankle plantarflexor tone: no increase in ankle plantarflexor tone (n=12), a slight increase in ankle plantarflexor tone (n=32), and a marked increase in ankle plantarflexor tone (n=17). Intervention: Not applicable. Main Outcome Measures: Reliability and absolute and relative MDC95 of the Berg Balance Scale (BBS), the lower limb subscale of Fugl-Meyer Assessment (FMA-LE), the Timed Up & Go test (TUG), the comfortable gait speed (CGS), the fast gait speed (FGS), and the 2-minute walk test (2MWT). Results: Excellent reliability of the BBS, FMA-LE, TUG, CGS, FGS, and 2MWT for all the participants combined and for the subgroups was shown. All the participants combined showed the absolute and relative MDC95 in the BBS of 5 points and 10%. FMA-LE of 4 points and 16%, TUG of 8 seconds and 28%, CGS of 0.2m/s and 34%, FGS of 0.1m/s and 21%, and 2MWT of 13m and 23%. The absolute and relative MDC95 of the subgroups were varied based on ankle plantarflexor tone. Conclusions: The BBS, FMA-LE, TUG, CGS, FGS, and 2MWT are reliable measures to detect postural balance and lower limb movements in individuals with chronic stroke who have differences in ankle plantarflexor tone. The absolute and relative MDC95 of each measure are dissimilar in those with differences in ankle plantarflexor tone. The relative MDC95 seems more useful than the absolute MDC95 because the relative value can be used for a single individual.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据