Experimental study on effective range of miniature oscillating heat pipes

期刊

APPLIED THERMAL ENGINEERING
卷 31, 期 5, 页码 880-886

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.applthermaleng.2010.11.009

关键词

Miniature oscillating heat pipes (MOHPs); Effective range; Dimensionless correlation prediction

资金

  1. NSFC [50876033]
  2. National Fund of Guang Dong Province [U0834002]
  3. Novark Technology INC.

向作者/读者索取更多资源

A series of experiments were performed to investigate the effect of heat transfer length and inner diameter on the heat transport capability of miniature oscillating heat pipes (MOHPs). In the experiments, MOHPs with heat transfer length (L) of 100, 150 and 200 mm, consisting of 4 meandering turns and inner diameter of 0.4, 0.8, 1.3 and 1.8 mm were adopted, and pure water was used as the working fluid. The results show that increasing inner diameter or decreasing heat transfer length is beneficial to MOHPs startup. An effective range of MOHPs has been identified. The recommended inner diameter of MOHPs should be bigger than 0.8 mm in vertical bottom heating mode, while the heat transfer length should be controlled less than approximately 100 mm in horizontal heating mode. For high heating power, the thermal performance of MOHPs can only approach that of sintered heat pipes in horizontal heating mode, while exceed it in vertical bottom heating mode. Finally, the dominating dimensionless parameters, including Di/L, Ja, Bo and Wa, are used to predict the heat transport capability of MOHPs. The correlation prediction agrees with the experimental results fairly well. (C) 2010 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据