4.4 Article

Real-time, in situ, continuous monitoring of CO in a pulverized-coal-fired power plant with a 2.3 μm laser absorption sensor

期刊

APPLIED PHYSICS B-LASERS AND OPTICS
卷 110, 期 3, 页码 359-365

出版社

SPRINGER HEIDELBERG
DOI: 10.1007/s00340-012-5262-8

关键词

-

向作者/读者索取更多资源

A real-time, in situ CO sensor using 2.3 mu m DFB diode laser absorption, with calibration-free wavelength-modulation-spectroscopy, was demonstrated for continuous monitoring in the boiler exhaust of a pulverized-coal-fired power plant up to temperatures of 700 K. The sensor was similar to a design demonstrated earlier in laboratory conditions, now refined to accommodate the harsh conditions of utility boilers. Measurements were performed across a 3 m path in the particulate-laden economizer exhaust of the coal-fired boiler. A 0.6 ppm detection limit with 1 s averaging was estimated from the results of a continuous 7-h-long measurement with varied excess air levels. The measured CO concentration exhibited expected inverse trends with the excess O-2 concentration, which was varied between 1 and 3 %. Measured CO concentrations ranged between 6 and 200 ppm; evaluation of the data suggested a dynamic range from 6 to 10,000 ppm based on a minimum signal-to-noise ratio of ten and maximum absorbance of one. This field demonstration of a 2.3 mu m laser absorption sensor for CO showed great potential for real-time combustion exhaust monitoring and control of practical combustion systems.