4.8 Article Proceedings Paper

Exergy analysis and the energy saving mechanism for coal to synthetic/substitute natural gas and power cogeneration system without and with CO2 capture

期刊

APPLIED ENERGY
卷 130, 期 -, 页码 552-561

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.apenergy.2014.03.036

关键词

Exergy analysis; Synthetic/substitute natural gas; IGCC/polygeneration; Carbon capture and storage; Energy saving mechanism

向作者/读者索取更多资源

The energy saving mechanism and the potential of efficiency improvement for coal to synthetic/substitute natural gas and power plant with different schemes and CO2 capture is disclosed through exergy analysis, and the effects of key parameters on exergy losses and system performance are investigated. Scheme A represents the system without CO2 capture but with a full syngas component adjustment and partial recycle of the chemical unconverted gas, Scheme B represents the system without CO2 capture and syngas component adjustment but with partial recycle of the chemical unconverted gas, and Scheme C represents the SNG and power cogeneration with CO2 capture and partial recycle of the chemical unconverted gas but without syngas component adjustment. Results show that the exergy efficiencies of Scheme A, B and C range from 56% to 62%, 57% to 67%, 52% to 62%, respectively. Coal gasification, water-gas-shift process, SNG methanation, and fuel combustion in combined cycle are identified as the main sources of exergy losses. Compared with Scheme A, the exergy efficiency of Scheme B is higher due to the avoidance of exergy losses from syngas adjustment. Scheme C is less energy efficient than Scheme B because of the CO2 capture. Compared with single product systems, the total exergy input of Scheme A, B and C can be reduced by 7.0-11.0%, 14.0-19.0%, 15.0-21.0%, respectively assuming the same product output. The chemical to power output ratio (CPOR) will impact the exergy losses of the whole plant greatly. For all schemes, with the increasing CPOR, the exergy losses for chemical synthesis island will increase whereas the exergy losses for power island will decrease. Especially high CPOR will cause sharp exergy losses of chemical synthesis island. The coupling between exergy losses for chemical synthesis and power islands leads to an optimal CPOR making the total exergy losses of the plant minimal and the system efficiency maximized. The results presented in this paper can help to confirm the potential of system integration and can be a guide for system integration. (C) 2014 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据