4.8 Article

Simulation of the influence of flue gas cleaning system on the energetic efficiency of a waste-to-energy plant

期刊

APPLIED ENERGY
卷 86, 期 9, 页码 1517-1523

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.apenergy.2008.12.035

关键词

Electrical efficiency; Waste incinerator; Simulation; Flue gas cleaning

向作者/读者索取更多资源

Municipal solid waste incinerators are designed to enhance the electrical efficiency obtained by the plant as much as possible. For this reason strong integration between the flue gas cleaning system and the heat recovery system is required. To provide higher electrical efficiencies acid gas neutralization process has the major importance in flue gas cleaning system. At least four technologies are usually applied for acid gas removal: dry neutralization with Ca(OH)(2) Or with NaHCO(3), semi-dry neutralization with milk of lime and wet scrubbing. Nowadays, wet scrubbers are rarely used as a result of the large amount of liquid effluents produced; wet scrubbing technology is often applied as a final treatment after a dry neutralization. Operating conditions of the plant were simulated by using Aspen Plus in order to investigate the influences of four different technologies on the electrical efficiency of the plant. The results of the simulations did not show a great influence of the gas cleaning system on the net electrical efficiency, as the difference between the most advantageous technology (neutralization with NaHCO(3)) and the worst one, is about 1%. (C) 2009 Elsevier Ltd. All rights reserved.