4.6 Article

Methoxy poly(ethylene glycol)-block-polycaprolactone copolymer: formulation and optimization by experimental design; determination of diblock molar mass by multivariate regression analysis of H-1 NMR spectra

期刊

ANALYTICAL METHODS
卷 5, 期 11, 页码 2840-2847

出版社

ROYAL SOC CHEMISTRY
DOI: 10.1039/c3ay26561g

关键词

-

向作者/读者索取更多资源

Recently, there was much attraction in amphiphilic block copolymers composed of methoxy poly(ethylene glycol) (MePEG) and biodegradable polyesters such as poly(caprolactone) (PCL). This copolymer significantly has applications in drug delivery systems. According to literature reports, efficiency of drug delivery and particle cellular uptake could be affected by many characteristics, such as particle size, different compositions of the particles, surface properties, different cell lines and cell densities, temperature. Hu et al. showed that the particle size is the key factor to determine the cellular uptake efficiency and it is found that the composition and molar mass of the copolymers are influential on the particle size. The present paper firstly discusses response surface methodology (RSM) as an efficient system for building a mathematical model and optimization of the apparent molar mass (M-n) by size-exclusion chromatography (SEC) (Y-1) and nuclear magnetic resonance (H-1 NMR) (Y-2). In this work, RSM is used to optimize the physical and chemical variables such as time, temperature, MePEG/CL and amount of Sn(Oct)(2). A 2(4) small factorial central composite design (CCD) was employed. After evaluation of experimental results, a 2F1 model was found to be fit for Y-1 response (SEC) and quadratic model for Y-2 (NMR) without any requirement of power transformation. The selection of model was done on basis of high adjusted R-2 value and lowered p-value for each model in individual analysis of each response. Through desirability analysis, it was found that SEC has a good precision/repeatability but a generally poor accuracy/reproducibility in determination of M-n. NMR is not suitable for determination of M-n for high molar mass PEG-PCL copolymers. Thus, the information that can be derived from NMR spectra is restricted because of broad and overlapping signals, poor solubility of polymers or non-availability of suitable solvents. NMR coupled with partial least squares (PLS) regression is applied to determine the M-n of MePEC in the present study. A PLS regression model with a coefficient of determination (R-2) of 0.8444 and root-mean-square error of cross validation (RMSECV) of 0.5625 was obtained in the spectral range delta 0.28-7.28 ppm. The results obtained in this study indicate that H-1 NMR spectroscopy can be used as an easy, rapid and novel tool to quantitatively predict the M-n of MePEC.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据