4.7 Article

The use of a polymer inclusion membrane in a paper-based sensor for the selective determination of Cu(II)

期刊

ANALYTICA CHIMICA ACTA
卷 803, 期 -, 页码 106-112

出版社

ELSEVIER
DOI: 10.1016/j.aca.2013.07.029

关键词

Polymer inclusion membrane (PIM); Paper based sensor (PBS); Detection of Cu(II); 1-(2-Pyridylazo)-2-naphthol (PAN); Di(2-ethlyhexyl) phosphoric acid (D2EHPA)

资金

  1. Australian Research Council [DP1094179]
  2. Australian Research Council [DP1094179] Funding Source: Australian Research Council

向作者/读者索取更多资源

A disposable paper-based sensor (PBS) is described for the determination of Cu(II) in natural and waste waters at approximately 2 cents per measurement. The device makes use of a polymer inclusion membrane (PIM) to provide the selectivity for Cu(II). The PIM consists of 40 wt% di(2-ethlyhexyl) phosphoric acid (D2EHPA) as the carrier, 10 wt% dioctyl phthalate (DOP) as a plasticizer, 49.5 wt% poly( vinyl chloride) (PVC) as the base polymer and 0.5 wt% (m m(-1)) 1-(2'-pyridylazo)-2-naphthol (PAN) as the colourimetric reagent. High selectivity under mildly acidic conditions (HC1, pH 2.0) is achieved for Cu(II) in the presence of frequently encountered metal ions in natural and waste waters such as Fe(III), Al(III), Zn(II), Cd(II), Pb(II), Ca(II), Mg(II), and Ni(II). The laminated PBS consists of a PIM sensing disc (2 mm in diameter) attached to the centre of a circular hydrophilic zone (7 mm in diameter) pretreated with 0.01 M HCl. This hydrophilic zone separates the sample port (a circular hole in the plastic cover) from the PIM sensing disc. After introducing 19.2 mu L, of a sample/standard solution to the sample port, Cu(II) diffuses across the hydrophilic zone and is extracted into the PIM disc as the Cu(II)-D2EHPA complex which subsequently reacts with PAN to produce the red-purple coloured Cu(II)-PAN complex. The colour intensity of the PIM disc is measured 15 min after sample/standard introduction by scanning using a flatbed scanner. Under optimal conditions the device is characterized by a limit of detection (LOD) and limit of quantitation (LOQ) of 0.06 and 0.21 mg L-1 Cu(II), respectively, with two linear ranges together covering the Cu(II) concentration range from 0.1 to 30.0 mg L-1.The PBS was successfully applied to the determination of Cu(II) in hot tap water and mine tailings water. (C) 2013 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据